International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ELU 200 external resistive load for the BTS 200 battery test system

External resistive load unit for the BTS 200 battery test system. It is connected when a discharge test needs more current than the BTS 200 can draw on its own, and it lets you set the discharge current at different voltage levels.

Type
external resistive load
Compatibility
BTS 200 battery test system
Units per system
up to 9
Settings
several discharge current configurations for different voltage levels

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ELU 200 is used during testing and maintenance of battery systems alongside the BTS 200 battery test system. It is connected when the BTS 200's own load is not enough and a discharge test calls for a higher current. Typical tasks include checking the capacity of stationary batteries at substations, in DC operational supply systems and in backup power sources.

In essence it is an additional resistive load. Each unit offers several configurations that can be switched to set the discharge current at different battery voltage levels, so one set of equipment can serve batteries with different nominal voltages and different discharge regimes.

Up to nine ELU 200 units can be connected to a single BTS 200. The total load is built up by adding units until the current required by the test programme is reached. The units act as an extension of the BTS 200, while the base system controls the discharge and records the results.

Each unit communicates with the BTS 200 over a USB interface and is made for that system specifically, working as its extension rather than as a standalone test instrument. When choosing how many units to use, the battery voltage, the required discharge current and the test duration are all taken into account. A resistive load turns the battery energy into heat during discharge, so the units should be placed where air can reach them freely. Before connection, check the configuration of each unit against the voltage level of the battery under test.

Technical specifications

Typeexternal resistive load
CompatibilityBTS 200 battery test system
Units per systemup to 9
Settingsseveral discharge current configurations for different voltage levels
InterfaceUSB
Applicationbattery testing and maintenance

Request a price and lead time

ELU 200 external resistive load for the BTS 200 battery test system. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many ELU 200 units can be connected?

Up to 9 ELU 200 units can be connected to a single BTS 200 system.

When is an ELU 200 needed?

When a discharge test on a battery requires more current than the BTS 200's own load can provide.

Can the discharge current be changed?

Yes, each unit has several configurations for setting the discharge current at different voltage levels.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides