
DRTS L relay test system for 1 A relays, 3 or 6 current channels
The DRTS L series has four models for testing relays, IEDs, energy meters and transducers with a nominal secondary current of 1 A. Current channels cover the 0.16 A, 1.6 A and 16 A ranges, and dedicated processors handle the IEC 61850 interface.
- Models
- DRTS 33L, 34L, 64L and 66L
- Current channels
- 3 or 6, up to 16 A
- Current ranges
- 0.16 A, 1.6 A, 16 A
- Power per current channel
- 3 x 100 VA at 8–16 A; 6 x 80 VA at 6–16 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Each of the four models is built around a different channel count. The DRTS 33L has 3 x 16 A and 3 x 300 V outputs, the DRTS 34L pairs 3 x 16 A with 4 x 300 V, the DRTS 64L offers 6 x 16 A with 4 x 300 V, and the DRTS 66L provides 6 x 16 A with 6 x 300 V. All of them handle single-phase and three-phase tests in analogue and digital modes.
The three-channel units deliver 3 x 100 VA at 8 to 16 A, and paralleling all their generators gives 1 x 48 A at 300 VA, with 48 A DC. The six-channel DRTS 64L and DRTS 66L provide 6 x 80 VA at 6 to 16 A. Pairing outputs yields 3 x 32 A and 3 x 160 VA, while connecting every generator in parallel gives 1 x 96 A at 480 VA. Voltage channels reach 300 V, at 50 VA each between 125 and 300 V, or 45 VA each on the DRTS 66L. Two generators in series produce 600 V at 100 VA, and DC power reaches 270 W at 300 V.
Accuracy in range 3 is better than 0.02% of reading plus 0.005% of range, with 0.25 mA, 0.1 mA and 0.05 mA resolution on the 16 A, 1.6 A and 0.16 A ranges. Frequency error is 0.5 ppm and the typical angle accuracy is ±0.02°. Eight digital inputs with 1 kV isolation accept up to 600 V DC for logging trips, and eight analogue inputs cover the 0.1, 1, 10, 100 and 425 V ranges. The four relay outputs switch 300 V and 10 A with a switching time under 5 ms, and an auxiliary DC supply provides 12 to 260 V at 50 W.
Separate processors handle IEC 61850: one publishes sampled values, which is an optional feature, and the other publishes and subscribes to GOOSE messages. In TDMS Pro, the Transcope function turns the analogue trip inputs into a multimeter, an oscilloscope, a data logger and a waveform recorder.
Class D amplifiers and the internal layout keep heat dispersion good, and the current and voltage modules can be removed for maintenance. Dimensions are 350 x 180 x 350 mm, with weight from 13.4 kg on the DRTS 33L to 16 kg on the DRTS 66L. A multi-position handle, tilt feet for horizontal use and two bumpers complete the design. The unit runs from 95 to 255 V AC at 47 to 63 Hz and draws up to 1200 W.
Technical specifications
| Models | DRTS 33L, 34L, 64L and 66L |
|---|---|
| Current channels | 3 or 6, up to 16 A |
| Current ranges | 0.16 A, 1.6 A, 16 A |
| Power per current channel | 3 x 100 VA at 8–16 A; 6 x 80 VA at 6–16 A |
| Largest single-phase current | 1 x 48 A (3 channels), 1 x 96 A (6 channels) |
| Voltage channels | 3, 4 or 6, up to 300 V |
| Single-phase voltage in series | 600 V, 100 VA |
| DC power | 270 W at 300 V |
| Current generator bandwidth | 0–2 kHz sinewave, 0–5 kHz transient |
| Current resolution | 0.25 mA / 0.1 mA / 0.05 mA |
| Digital inputs | 8, 1 kV isolation, up to 600 V DC |
| Analogue inputs | 8, ranges 0.1 / 1 / 10 / 100 / 425 V |
| Relay outputs | 4 relays, 300 V, 10 A |
| Auxiliary DC supply | 12–260 V DC, 50 W |
| Power supply | 95–255 V AC, 47–63 Hz, up to 1200 W |
| Dimensions | 350 x 180 x 350 mm |
| Weight | 13.4 / 13.6 / 15.8 / 16 kg |
Part numbers
Show all part numbers (4)
DRTS 33L, DRTS 34L, DRTS 64L, DRTS 66L
Request a price and lead time
DRTS L relay test system for 1 A relays, 3 or 6 current channels. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does the L series differ from the standard DRTS models?
The L series is built for relays with 1 A secondary current. Its channels go up to 16 A across the 0.16 A, 1.6 A and 16 A ranges, which gives finer resolution at low currents. The units are lighter, weighing from 13.4 to 16 kg.
Can the L series work with digital substations?
Yes. Dedicated processors handle GOOSE and, as an option, sampled values under IEC 61850-9-2LE, with time synchronisation under IEEE 1588-2008 and IRIG-B.
Which model should be used for differential protection?
Differential protection needs six current channels, so the DRTS 64L or DRTS 66L. The DRTS 66L also has six voltage channels.
Similar equipment from other manufacturers






