DRTS L relay test system for 1 A relays, 3 or 6 current channels

The DRTS L series has four models for testing relays, IEDs, energy meters and transducers with a nominal secondary current of 1 A. Current channels cover the 0.16 A, 1.6 A and 16 A ranges, and dedicated processors handle the IEC 61850 interface.

Models
DRTS 33L, 34L, 64L and 66L
Current channels
3 or 6, up to 16 A
Current ranges
0.16 A, 1.6 A, 16 A
Power per current channel
3 x 100 VA at 8–16 A; 6 x 80 VA at 6–16 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Each of the four models is built around a different channel count. The DRTS 33L has 3 x 16 A and 3 x 300 V outputs, the DRTS 34L pairs 3 x 16 A with 4 x 300 V, the DRTS 64L offers 6 x 16 A with 4 x 300 V, and the DRTS 66L provides 6 x 16 A with 6 x 300 V. All of them handle single-phase and three-phase tests in analogue and digital modes.

The three-channel units deliver 3 x 100 VA at 8 to 16 A, and paralleling all their generators gives 1 x 48 A at 300 VA, with 48 A DC. The six-channel DRTS 64L and DRTS 66L provide 6 x 80 VA at 6 to 16 A. Pairing outputs yields 3 x 32 A and 3 x 160 VA, while connecting every generator in parallel gives 1 x 96 A at 480 VA. Voltage channels reach 300 V, at 50 VA each between 125 and 300 V, or 45 VA each on the DRTS 66L. Two generators in series produce 600 V at 100 VA, and DC power reaches 270 W at 300 V.

Accuracy in range 3 is better than 0.02% of reading plus 0.005% of range, with 0.25 mA, 0.1 mA and 0.05 mA resolution on the 16 A, 1.6 A and 0.16 A ranges. Frequency error is 0.5 ppm and the typical angle accuracy is ±0.02°. Eight digital inputs with 1 kV isolation accept up to 600 V DC for logging trips, and eight analogue inputs cover the 0.1, 1, 10, 100 and 425 V ranges. The four relay outputs switch 300 V and 10 A with a switching time under 5 ms, and an auxiliary DC supply provides 12 to 260 V at 50 W.

Separate processors handle IEC 61850: one publishes sampled values, which is an optional feature, and the other publishes and subscribes to GOOSE messages. In TDMS Pro, the Transcope function turns the analogue trip inputs into a multimeter, an oscilloscope, a data logger and a waveform recorder.

Class D amplifiers and the internal layout keep heat dispersion good, and the current and voltage modules can be removed for maintenance. Dimensions are 350 x 180 x 350 mm, with weight from 13.4 kg on the DRTS 33L to 16 kg on the DRTS 66L. A multi-position handle, tilt feet for horizontal use and two bumpers complete the design. The unit runs from 95 to 255 V AC at 47 to 63 Hz and draws up to 1200 W.

Technical specifications

ModelsDRTS 33L, 34L, 64L and 66L
Current channels3 or 6, up to 16 A
Current ranges0.16 A, 1.6 A, 16 A
Power per current channel3 x 100 VA at 8–16 A; 6 x 80 VA at 6–16 A
Largest single-phase current1 x 48 A (3 channels), 1 x 96 A (6 channels)
Voltage channels3, 4 or 6, up to 300 V
Single-phase voltage in series600 V, 100 VA
DC power270 W at 300 V
Current generator bandwidth0–2 kHz sinewave, 0–5 kHz transient
Current resolution0.25 mA / 0.1 mA / 0.05 mA
Digital inputs8, 1 kV isolation, up to 600 V DC
Analogue inputs8, ranges 0.1 / 1 / 10 / 100 / 425 V
Relay outputs4 relays, 300 V, 10 A
Auxiliary DC supply12–260 V DC, 50 W
Power supply95–255 V AC, 47–63 Hz, up to 1200 W
Dimensions350 x 180 x 350 mm
Weight13.4 / 13.6 / 15.8 / 16 kg

Part numbers

Show all part numbers (4)

DRTS 33L, DRTS 34L, DRTS 64L, DRTS 66L

Request a price and lead time

DRTS L relay test system for 1 A relays, 3 or 6 current channels. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the L series differ from the standard DRTS models?

The L series is built for relays with 1 A secondary current. Its channels go up to 16 A across the 0.16 A, 1.6 A and 16 A ranges, which gives finer resolution at low currents. The units are lighter, weighing from 13.4 to 16 kg.

Can the L series work with digital substations?

Yes. Dedicated processors handle GOOSE and, as an option, sampled values under IEC 61850-9-2LE, with time synchronisation under IEEE 1588-2008 and IRIG-B.

Which model should be used for differential protection?

Differential protection needs six current channels, so the DRTS 64L or DRTS 66L. The DRTS 66L also has six voltage channels.