
DRTS 64 relay protection test kit with 6 current and 4 voltage outputs
The DRTS 64 provides six current generators, four voltage generators and a battery simulator. Six current channels suit differential protection of transformers and lines, multi-phase relays and high-burden relays.
- Generators
- 6 current, 4 voltage and battery simulator
- Current outputs
- six of 0–32 A, three of 0–64 A, one of 0–128 A
- Current output power
- six at 430 VA (32 A), three at 860 VA (64 A), one at 1000 VA (64 A)
- Voltage outputs
- four of 0–300 V at 100 VA, one of 0–600 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Six current outputs deliver 0 to 32 A each. Connected in parallel they form three 0 to 64 A channels or one 0 to 128 A channel. Output power reaches 430 VA per channel at 32 A, 860 VA on each of the three 64 A channels and 1000 VA on a single output. Four voltage outputs give 0 to 300 V at 100 VA each, and a series connection gives 0 to 600 V.
Typical accuracy is ±0.02% of reading plus ±0.01% of range, and the guaranteed figure is 0.04% of reading plus 0.01% of range. Distortion is 0.05% typically and 0.15% guaranteed. Resolution is 0.1 mA at 32 A, 0.4 mV at 12.5 V and 10 mV at 300 V. The waveform is generated with 32-bit resolution from a 50 kHz DAC, giving an output frequency range of 0 to 3 kHz that extends to 5 kHz when playing back recordings.
Twelve digital inputs accept 4.5 to 300 V DC. The timer resolves 0.01 ms with an accuracy of 0.001% of the measured value plus 0.1 ms, and debounce can be set from 40 μs to 2 ms. Pulse counting runs up to 100 kHz. The DC measuring inputs cover ±5 mA, ±20 mA and ±10 V, with resolutions of 10 nA and 10 µV, which suits transducer checks. Four make-and-break outputs switch 300 V, 8 A and 2400 VA AC, or 300 V, 8 A and 50 W DC.
The unit runs from a single-phase 85 to 264 V AC supply at 45 to 65 Hz and uses a standard 20 A plug. It is protected against mains overvoltage between 275 V and 400 V. Standby draw is below 150 W, while full load consumption is 1600 W on a 115 V mains and 2700 W on 230 V. The aluminium 3U rack enclosure measures 150 x 466 x 423 mm and is rated IP2x. It operates between 0 and 55 °C, is stored between -25 and 70 °C and is rated for altitudes below 2000 m.
Typical applications cover protection on transmission and distribution networks, smart grid equipment, single-phase, three-phase and multi-phase units, high-burden and low-power devices, and DC circuits. The set also tests energy meters, transducers and power quality meters. Engineers use it for commissioning and maintenance at substations, including checks on line differential schemes.
Technical specifications
| Generators | 6 current, 4 voltage and battery simulator |
|---|---|
| Current outputs | six of 0–32 A, three of 0–64 A, one of 0–128 A |
| Current output power | six at 430 VA (32 A), three at 860 VA (64 A), one at 1000 VA (64 A) |
| Voltage outputs | four of 0–300 V at 100 VA, one of 0–600 V |
| Accuracy | typically ±0.02% of reading ±0.01% of range |
| Distortion | typically 0.05%, guaranteed 0.15% |
| Output frequency | 0–3 kHz, 5 kHz when playing back recordings |
| Battery simulator | 0…260 V DC, 1 A, 50 W |
| Digital inputs | 12, 4.5–300 V DC |
| Timer resolution | 0.01 ms |
| Digital outputs | 4; AC 300 V, 8 A, 2400 VA; DC 300 V, 8 A, 50 W |
| Interfaces | IEC 61850, USB, Ethernet |
| Display | 5.7 inch, 320 x 240 pixels |
| Mains supply | 85–264 V AC, 45–65 Hz |
| Dimensions | 150 x 466 x 423 mm |
| Operating temperature | 0–55 °C |
| Degree of protection | IP2x |
Part numbers
Show all part numbers (2)
35170, 30170
Request a price and lead time
DRTS 64 relay protection test kit with 6 current and 4 voltage outputs. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Is the DRTS 64 suitable for testing differential protection?
Yes. Its six 32 A current outputs can inject currents at both ends of the protected equipment at the same time, and the manufacturer lists multi-phase and high-burden relays among its applications.
What is the highest current the set can deliver?
With all current outputs connected in parallel the set delivers 1 x 128 A. Connecting them in pairs gives 3 x 64 A, with 860 VA per phase.
What mains supply does the DRTS 64 need?
A single-phase supply of 85 to 264 V AC at 45 to 65 Hz, connected through a standard 20 A plug. Under full load it draws 2700 W from a 230 V mains.
Similar equipment from other manufacturers






