CT-3500 S2 digital timer for circuit breakers, 3 channels and built-in printer
The CT-3500 S2 is a standalone second generation microprocessor timer for circuit breakers. It measures the time from the application of voltage to the coil until the breaker dry contacts open or close, and shows the result on a display and a built-in thermal printer.
- Type
- portable circuit breaker analyser
- Dry contact inputs
- 3 channels
- Start voltage
- 24–300 V DC or peak AC
- Breaker operations
- opening, closing, open-close, close-open
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The CT-3500 S2 digital timer checks the timing characteristics of circuit breakers, as well as relays and other switching devices that operate from a start voltage of 24–300 V DC or AC. It runs without a computer, which makes it suitable for field measurements at substations.
A single start voltage triggers three independent electronic timers at once. Each timer stops when its own dry contact closes or opens, so three poles are measured in one operation. The instrument analyses every breaker operation: opening, closing, open-close and close-open. Main contacts and pre-insertion resistor contacts are measured on the same input. Resolution is ±0.1 ms, accuracy is 0.05 % of reading ± 0.1 ms, and results are shown in milliseconds and in cycles.
All contact sync inputs are shorted to earth until the test starts and protected against electrostatic discharge, and the dry contact channels have a fuse. A self-test mode checks the cables and the connection to the breaker before measurement.
Control is handled through a 44-key membrane QWERTY keypad, and results appear on a backlit LCD of 128 x 64 pixels. A built-in thermal printer 2.5 inches wide prints test reports. Memory keeps up to 128 test records, and there is a USB port for connection to a PC plus a port for a USB memory stick. The breaker analysis program is included, through which records can be transferred to a PC, viewed and exported.
Power input is 100–240 V AC, 50/60 Hz. Dimensions are 40.6 x 17.4 x 33 cm and mass is 6.4 kg. The operating temperature is -10 to +50 °C, storage -30 to +70 °C, and humidity up to 90 % at 40 °C without condensation. The unit conforms to CSA-C22.2, UL61010A-1 and IEC61010 (1995). The kit includes contact cables of 6.10 m with 9.14 m extensions, a 4.57 m start cable, a 1.83 m USB cable and a combined power and earth cable.
Technical specifications
| Type | portable circuit breaker analyser |
|---|---|
| Dry contact inputs | 3 channels |
| Start voltage | 24–300 V DC or peak AC |
| Breaker operations | opening, closing, open-close, close-open |
| Resolution | ± 0.1 ms |
| Accuracy | 0.05 % of reading ± 0.1 ms |
| Display | backlit LCD, 128 x 64 pixels |
| Keypad | membrane QWERTY, 44 keys |
| Printer | thermal, 2.5 inch width |
| Memory | up to 128 records |
| Interfaces | USB for PC, USB memory stick |
| Power supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 40.6 x 17.4 x 33 cm |
| Weight | 6.4 kg |
| Operating temperature | -10...+50 °C |
| Storage temperature | -30...+70 °C |
| Safety | CSA-C22.2, UL61010A-1 and IEC61010 (1995) |
Part numbers
Show all part numbers (8)
8000-0098, 8000-0096, 8000-0095, 8000-0016, 8000-0005, TP3-CS, 9002-SC, 9002-UC
Request a price and lead time
CT-3500 S2 digital timer for circuit breakers, 3 channels and built-in printer. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many contacts are measured at the same time?
Three independent timers start from the same start voltage, and each stops on its own dry contact, so three channels are measured in one operation.
Can pre-insertion resistor contacts be measured?
Yes, the main contacts and the pre-insertion resistor contacts are measured on the same input.
How are results stored?
Up to 128 records are kept in internal memory, printed on the built-in printer, and transferred to a PC through USB or saved to a USB memory stick.