CL series — motor core loss test sets for motors up to 20000 hp
The CL series checks core loss in the stators, rotors and armatures of AC and DC motors rated up to 20000 hp. Testing confirms motor quality and supports rewinds, and it also locates local overheating caused by shorted laminations.
- Motor rating
- Up to 20000 hp
- Test objects
- Stators, rotors, armatures
- Accuracy of transducers
- 0.2 % of reading
- Communications
- Ethernet
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Excessive core loss lowers motor efficiency and shortens its service life. Core damage includes shorts between laminations and damage that follows a winding failure. During a rewind, the core is tested before the windings are removed to reveal defects, and tested again after removal to confirm that it has not been damaged. A motor with a damaged core can keep running, but it draws more power and runs hotter, and a rise of 10°C in winding temperature can halve the insulation life.
The sets work with all types of AC and DC motor, including traction, synchronous and induction machines, and with shunt, compound and series excitation. The unit is a smoothly adjustable low-voltage source of high current with very low distortion that does not depend on load or setting. Its output is a true sine wave, which keeps the results accurate and repeatable.
The base package includes measuring instruments, output and voltmeter leads, a computer and a printer. The operator connects the terminals, enters the parameters and presses a button, after which the unit raises the voltage, logs the readings, performs the calculations and lowers the voltage again. Messages warn of connection errors. A motor database is kept by the software, so repeat tests can be compared easily for trend analysis, and the program works with a programmable logic controller that governs each test stage.
Output is adjusted by a motorised regulator with a variable rise rate, and each output tap has 3-5 sub-ranges, giving 3 to 5 times finer adjustment. Meters are calibrated from the computer without removing panels. Sustained loading lets the core be re-excited and warmed for hot-spot location. The updated version has a new controller, transducers accurate to 0.2 % of reading and an Ethernet interface.
Protection features include a main circuit breaker, fuses in the control circuits, an emergency stop button, a start-from-zero interlock, an external interlock, thermal protection, and internal, external and transient overload protection. The cabinet is steel. The CL10B, CL25B, CL60B and CL125B have wheels, a lockable lid and a cable hook, and the range includes the CL10B, CL25B, CL60B, CL125B, CL300B and CL500B.
Technical specifications
| Motor rating | Up to 20000 hp |
|---|---|
| Test objects | Stators, rotors, armatures |
| Accuracy of transducers | 0.2 % of reading |
| Communications | Ethernet |
| Output waveform | True sine wave |
| Control | Programmable logic controller, computer |
| Regulation | Motorised regulator, 3-5 ranges per tap |
| Protection | Start-from-zero interlock, thermal protection, emergency stop |
| Enclosure | Steel cabinet |
Part numbers
Show all part numbers (6)
CL10B, CL25B, CL60B, CL125B, CL300B, CL500B
Request a price and lead time
CL series — motor core loss test sets for motors up to 20000 hp. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
When is core loss tested during a motor rewind?
Before the old windings are removed, to reveal core damage, and again after removal, to confirm the core has not been damaged.
Can hot spots in the core be located?
Yes. The extended loading function re-excites and warms the core, which shows up shorted laminations that cause local overheating.
Which models have wheels?
The CL10B, CL25B, CL60B and CL125B have wheels, a lockable lid and a cable hook.