BU 2000 and BU 4000 High Current Boosters for Primary Injection, up to 4000 A

The BU 2000 and BU 4000 complement T 2000 and T 3000 primary injection and transformer test sets. Each module generates up to 4000 A close to the object and removes the power losses in long high current cables.

Current limit
up to 4000 A
Versions
BU 2000 (2000 A), BU 4000 (4000 A)
Purpose
primary current injection, transformer testing
Compatible sets
T 2000, T 3000

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The BU 2000 and BU 4000 boosters are options for the T 2000 and T 3000 primary current injection sets. They are used when testing circuit breakers, protection relays and current transformers where the object is far from the main instrument, and long high current cables lose much of the power in their resistance and inductance.

The design separates control from current generation. The main T 2000 or T 3000 unit stays in a convenient place, and the booster is placed beside the test object. A low power control cable up to 20 m long links them, and the high current flows only through short cables between booster and object. This reduces losses in the circuit, so the set delivers more current from the same supply.

The BU 2000 version is rated for tests at 2000 A and the BU 4000 for currents up to 4000 A. Both modules perform ratio and polarity checks of current transformers, as well as high current primary injection tests. The booster is supplied with high current clamps and high current cables for connection to busbars or equipment terminals.

Test modes, settings and recording of results are entered from the main T 2000 or T 3000 unit, so no separate controls are needed on the booster. The module is used during commissioning and periodic checks of substation equipment where a large primary current is needed far from the operator. To check current transformers on site, the booster gives the rated or raised primary current without moving heavy cables.

Technical specifications

Current limitup to 4000 A
VersionsBU 2000 (2000 A), BU 4000 (4000 A)
Purposeprimary current injection, transformer testing
Compatible setsT 2000, T 3000
Control cablelow power, maximum length 20 m
Tests2000 A and 4000 A high current tests, CT ratio and CT polarity
Kit contentshigh current clamps and cables

Request a price and lead time

BU 2000 and BU 4000 High Current Boosters for Primary Injection, up to 4000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sets does the booster work with?

The BU 2000 and BU 4000 connect to the T 2000 and T 3000 primary injection sets and are controlled from them.

How far can the booster be placed from the main unit?

It is linked to the T 2000 or T 3000 by a low power control cable up to 20 m long.

Which current transformer checks are available?

Ratio and polarity checks of current transformers, as well as high current tests at 2000 A or 4000 A.