BK130/36 and BK300 — mobile AC insulation test sets for aerial lifts, up to 300 kV
The BK series mobile test sets apply high AC voltage to aerial lifts, mobile work platforms and insulated booms. They meet the ANSI A92.2 and IEC requirements for such machines, and the BK130/36 also tests double and horseshoe basket liners.
- BK130/36
- 0-130 kV AC, 50 mA; 0-36 kV AC, 180 mA
- BK130/36-B
- 0-130 kV AC, 50 mA; 0-36 kV AC, 180 mA; touch screen
- BK300
- 0-300 kV AC, 60 mA; touch screen
- Standards
- ANSI A92.2-2015, IEC 61813, IEC 61057
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The units are supplied as complete portable systems, so one machine can be tested in the field or a whole fleet can be checked on a regular schedule. The enclosure is light yet tough, designed for long periods of outdoor use, and setup and operation are straightforward. The sets are also suitable for routine dielectric and insulation tests on other equipment.
Three models are offered. The BK130/36 and BK130/36-B are listed with ranges of 0-130 kV AC at 50 mA and 0-36 kV AC at 180 mA, while the BK300 delivers 0-300 kV AC at 60 mA. The base model reads its output on easy-to-view digital meters, whereas the BK130/36-B and BK300 use a touch screen with auto-ranging meters, automatic operation and data acquisition.
The high-voltage section is oil-filled and sealed in a fibreglass-reinforced vessel, which keeps it light and resistant to field conditions. The precision measuring system includes guard circuits that divert stray leakage currents, so only the leakage current flowing through the boom is measured. The unit uses reactive compensation to reduce the power drawn from the supply mains.
Protection features include a start-from-zero interlock, adjustable output overload protection and thermal-magnetic protection against short and long overloads. A main supply circuit breaker is fitted, with an indicator on the base model, and an external warning circuit can be connected for safety devices. The sets meet the standard covered by ANSI A92.2 and the one covered by IEC 61813, and the brochure cites ANSI A92.2-2015 and IEC 61057. Calibration is traceable to Canada's national metrology institute, and ISO 17025 calibration with uncertainty analysis is available on request.
Technical specifications
| BK130/36 | 0-130 kV AC, 50 mA; 0-36 kV AC, 180 mA |
|---|---|
| BK130/36-B | 0-130 kV AC, 50 mA; 0-36 kV AC, 180 mA; touch screen |
| BK300 | 0-300 kV AC, 60 mA; touch screen |
| Standards | ANSI A92.2-2015, IEC 61813, IEC 61057 |
| High-voltage section | Oil-filled, sealed fibreglass vessel |
| Measurement | Precision, with guard circuits against stray leakage currents |
| Protection | Start-from-zero interlock, adjustable overload protection, thermal-magnetic protection |
| Calibration | ISO 17025 with uncertainty analysis (optional) |
Part numbers
Show all part numbers (3)
BK130/36, BK130/36-B, BK300
Request a price and lead time
BK130/36 and BK300 — mobile AC insulation test sets for aerial lifts, up to 300 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which model should be chosen for testing basket liners?
Double and horseshoe liners are tested with the BK130/36, which provides 0-130 kV at 50 mA and 0-36 kV at 180 mA.
Do leakage currents along the surface of the unit affect the result?
No. The measuring system has guard circuits that divert stray currents, so only the leakage current through the boom is measured.
Which models include data acquisition?
The BK130/36-B and BK300 have a touch screen with auto-ranging meters, automatic operation and data acquisition.