AC/DC kilovoltmeter with high-voltage divider, 50–300 kV
AC/DC kilovoltmeters combine a resistive-capacitive voltage divider with a measuring unit, for calibration and general high voltage measurement. Calibration is traceable to NIST, and standard models cover 50–300 kV.
- Measurement span
- 50 kV to 300 kV (higher on request)
- Measuring functions
- AC Average, AC RMS, AC Peak, AC Peak/√2, DC Average, DC Peak, DC Ripple
- Divider type
- resistive-capacitive
- Division ratio
- 10000:1
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The instrument measures high voltage, both alternating and direct, on test rigs in the laboratory and in the field. Its functions cover average, RMS and peak values of AC voltage, peak divided by √2, average and peak values of DC voltage, and DC ripple. The divider can also feed other instruments, such as an oscilloscope or a multimeter.
The kit includes the high-voltage divider, the measuring unit and connecting cables, all stored in a compact, rugged case. The divider is resistive-capacitive, and the instrument conforms to IEC 60060-2 and IEEE Std 4. Standard models cover 50 to 300 kV, and higher voltages are made to order.
Options include the DVD100, DVD200 and DVD300 dividers rated at 100, 200 and 300 kV with a 10000:1 ratio, plus the KVM metering head, which works with a 10000:1 divider. A 19-inch rack-mount version of the head is also available. Other division ratios can be manufactured on request.
The modular precision divider comes apart easily for transport while keeping its stability and low ratio error. The largest single part is under 900 mm (37 in) long and weighs less than 35 kg (80 lb). It serves as the primary reference for on-site calibration of precision AC and DC ultra-high-voltage measuring systems, and transit cases are available as an option.
The measuring unit has a 4½-digit LCD, a switch for the low and high ranges, and indicators for mains power and battery charge. It runs from mains or a Ni-MH battery. Operating conditions range from 0 to 40 °C indoors or outdoors in dry weather, humidity below 95% non-condensing, and altitude up to 1000 m (3300 ft). Storage is from 0 to 55 °C in a dry room.
Technical specifications
| Measurement span | 50 kV to 300 kV (higher on request) |
|---|---|
| Measuring functions | AC Average, AC RMS, AC Peak, AC Peak/√2, DC Average, DC Peak, DC Ripple |
| Divider type | resistive-capacitive |
| Division ratio | 10000:1 |
| Display | LCD, 4½ digits |
| Power supply | mains or Ni-MH battery |
| Operating temperature | 0 to 40 °C |
| Humidity | below 95% non-condensing |
| Altitude | below 3300 ft (1000 m) |
| Storage temperature | 0 to 55 °C |
| Largest divider part | under 900 mm (37 in), under 35 kg (80 lb) |
| Conformity | IEC 60060-2, IEEE Std 4 |
| Traceability | NIST |
Part numbers
Show all part numbers (4)
DVD100, DVD200, DVD300, KVM
Request a price and lead time
AC/DC kilovoltmeter with high-voltage divider, 50–300 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which dividers can be used with the kilovoltmeter?
The DVD100, DVD200 and DVD300 cover 100, 200 and 300 kV with a 10000:1 ratio. The KVM metering head works with the 10000:1 divider.
Can the divider be used with an oscilloscope?
Yes. The divider can be connected to other measuring instruments, such as an oscilloscope or a multimeter.
Is the instrument suitable for calibration on site?
Yes. The modular divider separates into sections under 900 mm long and under 35 kg, and serves as the primary reference for calibrating high-voltage measuring systems on site.
Similar equipment from other manufacturers