4CC Modular DC Test Systems up to 1000 kV, Stackable 300 and 500 kV Modules
The 4CC modular series performs high voltage DC insulation testing and serves as a high voltage power source for laboratories. Modules of 300 kV or 500 kV are stacked to build systems up to 1000 kV, with outputs of 20 mA and 50 mA.
- Models
- 4CC300-20, 4CC500-20, 4CC600-20, 4CC1000-20
- Voltage
- 300 kV, 500 kV, 600 kV, 1000 kV
- Modules
- 300 x 1, 500 x 1, 300 x 2, 500 x 2
- Stacking step
- 300 kV or 500 kV modules
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
These systems test insulation on cables, transformers, insulators, bushings and converter valves to IEC 62501 and IEC 60700. They suit HVDC withstand tests and partial discharge measurements across the whole of a direct current transmission installation. They are also used as a high voltage power source for research tests, evaluation work and teaching demonstrations.
High voltage is generated by a cascaded full-wave voltage doubler. This gives large charging currents and low output ripple, and the system's own partial discharge level is low. Polarity is switched quickly by a motorised drive. An internal voltage divider allows voltage to be measured directly, in line with IEEE Standard 4 and IEC 60060-2. An output series resistor is included in the kit.
For higher voltages the 300 kV or 500 kV modules are stacked one on top of another. In the range, the 4CC300-20 has one 300 kV module, is 12 ft (3.6 m) high and weighs 1.5 t. The 4CC500-20 has one 500 kV module, is 15 ft (4.6 m) high and weighs 2 t. The 4CC600-20 is built from two 300 kV modules to reach 600 kV, stands 25 ft (7.5 m) high and weighs 3 t. The 4CC1000-20 combines two 500 kV modules to give 1000 kV, is 32 ft (9.75 m) high and weighs 4.5 t. Current in this series is up to 20 mA, and 10 mA continuous.
Options include a combined divider, discharge and earthing device, a separate discharge unit, an earthing switch and capacitors for partial discharge measurement. Wheels or an air platform are available for moving the unit. The insulating enclosure is either a smooth FRP fibreglass housing for laboratories or a ribbed composite insulator for long-term industrial use. A PC software package collects the data and produces test reports.
Technical specifications
| Models | 4CC300-20, 4CC500-20, 4CC600-20, 4CC1000-20 |
|---|---|
| Voltage | 300 kV, 500 kV, 600 kV, 1000 kV |
| Modules | 300 x 1, 500 x 1, 300 x 2, 500 x 2 |
| Stacking step | 300 kV or 500 kV modules |
| Output current | 20 mA and 50 mA; 4CC-20 series up to 20 mA, 10 mA continuous |
| Height | 12 ft (3.6 m), 15 ft (4.6 m), 25 ft (7.5 m), 32 ft (9.75 m) |
| Weight | 1.5 t, 2 t, 3 t, 4.5 t |
| Circuit | cascaded full-wave voltage doubler |
| Polarity switching | motorised |
| Voltage measurement | internal divider, IEEE Standard 4, IEC 60060-2 |
| Valve testing | IEC 62501, IEC 60700 |
| Enclosure | smooth FRP or ribbed composite insulator |
Part numbers
Show all part numbers (4)
4CC300-20, 4CC500-20, 4CC600-20, 4CC1000-20
Request a price and lead time
4CC Modular DC Test Systems up to 1000 kV, Stackable 300 and 500 kV Modules. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How is a voltage above a single module's rating reached?
The 300 kV or 500 kV modules are stacked one on top of the other. Two 500 kV modules in the 4CC1000-20 give 1000 kV.
Can partial discharge be measured?
Yes. The systems suit partial discharge measurements on HVDC equipment, the installation's own discharge level is low, and capacitors for this measurement are supplied as an option.
Which enclosure suits a workshop?
For long-term use in an industrial environment the ribbed composite insulator is chosen, while the smooth FRP fibreglass housing is intended for laboratories.