International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TS2 group-operated side-break air switches, 27–145 kV, for overhead transmission lines

Pole-mounted air switches with a side-break blade and aluminium live parts for overhead lines. The TS2 family spans 27 kV to 145 kV and 600, 1200 or 2000 A, in one-way, two-way and three-way builds.

Type
side break, group operated
Voltage rating
27–145 kV
Current rating
600, 1200 or 2000 A
Live parts
aluminium

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On a crowded transmission corridor the frame matters as much as the contacts. The two-way TU-2TS2 and three-way TU-3TS2 sit phase over phase, or phase opposite phase, on a lightweight aluminium frame bolted straight to the pole, so cross arms and braces are left out and less land is taken for the line. Wood, steel, concrete and laminated wood poles are all suitable.

Single-way positions are covered by the TU-1TS2U, a unitised switch built on a one-piece mount. It leaves the works assembled and adjusted, which cuts fitting time on site, and it can go vertical, underhung, face mounted, pole top or mid pole. TU-1CS2 and TU-1AS2 add further one-way phase-over-phase versions.

Ratings run from 27 kV to 145 kV, with current ratings of 600 A, 1200 A or 2000 A. The blade swings sideways out of the jaw, so little headroom is needed above the phase. Hot parts are aluminium, and the switches are meant for full-load service with a group operating mechanism.

Every order starts with a mounting data sheet. It records pole dimensions and line angles, conductor tensions on the left, right and tap, pole shape (round, multi-sided or rectangular), top diameter, taper and the fixing method, either through-bolts or brackets welded to the pole by its supplier. The installation manual then walks through blade and jaw alignment, horizontal and vertical adjustment, the blade latch, the swing handle or worm gear drive, pipe piercing for interconnection, and opening and closing. Adjacent equipment must be de-energised and earthed first, and only qualified staff should do the work.

Technical specifications

Typeside break, group operated
Voltage rating27–145 kV
Current rating600, 1200 or 2000 A
Live partsaluminium
Buildsone-way, two-way, three-way
Phase arrangementphase over phase, phase opposite phase
TU-1TS2U mountingvertical, underhung, face mount, pole top, mid pole
Pole materialwood, steel, concrete, laminated wood
Fixing to polethrough-bolts or welded brackets
ModelsTU-1TS2U, TU-2TS2, TU-3TS2, TU-1CS2, TU-1AS2

Request a price and lead time

TS2 group-operated side-break air switches, 27–145 kV, for overhead transmission lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What voltage and current does the TS2 family cover?

Voltage ratings run from 27 kV to 145 kV, and current ratings are 600 A, 1200 A or 2000 A.

How does the TU-1TS2U differ from the TU-2TS2 and TU-3TS2?

The TU-1TS2U is a single-way unitised switch on a one-piece mount, shipped assembled and adjusted. The TU-2TS2 and TU-3TS2 are two-way and three-way switches on a light aluminium frame arranged phase over phase.

Which pole types can the switches be fitted to?

The frames suit wood, steel, concrete and laminated wood poles without cross arms. Multi-sided steel poles can take the switch on welded brackets instead of through-bolts.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides