TECORupter vacuum interrupter for disconnectors up to 245 kV, 2000 and 3000 A

The TECORupter is a vacuum attachment for disconnectors that allows loop, charging and magnetising currents to be broken under load. It is made in 2000 A and 3000 A versions for networks from 15 kV to 245 kV and complies with IEEE 1247.

Type
vacuum interrupter attachment for disconnectors
Rated current
2000 A; 3000 A
Voltage classes
15, 27, 38, 48, 72, 123, 145, 170, 245 kV
Maximum at 2000 A
245 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The interrupter is mounted on disconnectors with centre, vertical and side break, both on the same manufacturer's equipment and on structures from other makers. When the disconnector opens, the arc is extinguished in a vacuum chamber rather than in air between the blades, so the device breaks the current in a controlled way in normal and fault conditions. Single-position versions are available, as well as two-way and three-way versions.

Models are divided by rated current, 2000 A and 3000 A, and by switching type. Full-voltage interrupters break the current when, after opening, voltage remains on one side of the disconnector only. Each vacuum contact withstands a recovery voltage peak of 50 kV. From 34.5 kV upwards several contacts are connected in series, while in 15 kV and 23 kV networks a single contact is enough. The limits are up to 245 kV at 2000 A and up to 27 kV at 3000 A.

Loop split versions have one contact. They are used where voltage remains on both sides after opening, and the voltage difference is usually less than 10% of the network voltage, which lies within the rating of one 50 kV or 80 kV contact. At higher recovery voltage, further contacts are added. Loop current is up to 3000 A at a lagging power factor above 70%.

These interrupters switch loop and parallel circuit currents up to 3000 A at a lagging power factor above 70%, as well as line charging currents and transformer magnetising currents up to 100 A at a leading power factor below 20%.

Limited Duty interrupters are used when the operating current exceeds the limits of the standard full-voltage versions, with the same electrical and switching parameters. The manufacturer's table lists classes of 15, 27, 38, 48, 72, 123, 145, 170 and 245 kV. To select a unit, state the type of disconnector, the current and the voltage. The installation manual covers receipt and inspection, testing of the interrupter, adjustment to the disconnector, the length of stroke, and the radius and height of the hook.

Technical specifications

Typevacuum interrupter attachment for disconnectors
Rated current2000 A; 3000 A
Voltage classes15, 27, 38, 48, 72, 123, 145, 170, 245 kV
Maximum at 2000 A245 kV
Maximum at 3000 A27 kV
Recovery voltage peak per contact50 kV (loop split: 50 kV or 80 kV)
Loop and parallel circuit currentup to 3000 A, lagging power factor above 70%
Charging and magnetising currentup to 100 A, leading power factor below 20%
Voltage difference at loop splitusually less than 10% of network voltage
Versionsfull voltage, loop split, Limited Duty
Number of directionsone; two and three
Disconnector typescentre, vertical, side break
StandardIEEE 1247

Request a price and lead time

TECORupter vacuum interrupter for disconnectors up to 245 kV, 2000 and 3000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the interrupter be fitted to a disconnector from another manufacturer?

Yes. TECORupter is supplied as an attachment and also fits disconnectors with centre, vertical or side break from other manufacturers. The disconnector type, current and voltage are needed to select a unit.

Which version should be used for a 123 or 145 kV network with 3000 A current?

The manufacturer's table limits full-voltage 3000 A versions to 27 kV, so at higher classes with 3000 A the loop split or Limited Duty options are considered. A full-voltage version up to 245 kV exists at 2000 A.

Can the interrupter break transformer magnetising current?

Yes. The full-voltage versions switch line charging and magnetising currents up to 100 A at a leading power factor below 20%.