The STB series are dry wall bushings that bring high voltage through a building wall or substation partition. Rated voltage runs from 40.5 to 252 kV and rated current from 100 to 3150 A, at 50 to 60 Hz.

Rated voltage
40.5 to 252 kV
Rated current
100 to 3150 A
Rated frequency
50 to 60 Hz
Ambient temperature
-50 to +45 °C

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

STB insulators are installed where a high voltage conductor or busbar passes through the wall of a closed switchgear room, substation building or enclosure. The insulator holds the live conductor rod, separates it from the earthed wall and withstands the system voltage on both sides of the partition. The series is used in transmission and distribution networks of the 40.5, 72.5, 126 and 245 kV classes.

The design is dry, with no oil filling, so the insulator needs no oil level checks and carries no risk of leakage inside the building. The manufacturer also supplies combined versions in which the wall bushing is paired with a current transformer. This combination reduces the number of devices at the entry point and the wall space they occupy.

The standard range covers eight models: STB 40.5/630, STB 40.5/3150, STB 72.5/630, STB 72.5/1600, STB 126/630, STB 126/2000, STB 245/630 and STB 245/2000. In the designation, the first number gives the rated voltage in kilovolts and the second the rated current in amperes. Overall length, the lengths of the parts on each side of the wall, creepage distance and mass depend on the voltage class and increase from the 40.5 kV models to the 245 kV models.

The insulators are rated for ambient temperatures from -50 to +45 °C. The specific creepage distance of the external insulation is between 25 and 31 mm/kV, which is taken into account when choosing the version for zones with different levels of atmospheric pollution.

The models listed correspond to typical operating conditions. For other voltages, operating conditions and entry configurations, the manufacturer designs the insulators for the specific task. Selection requires the voltage class, rated current, wall thickness, creepage requirements and the climatic conditions at the site.

Technical specifications

Rated voltage40.5 to 252 kV
Rated current100 to 3150 A
Rated frequency50 to 60 Hz
Ambient temperature-50 to +45 °C
Specific creepage distance25 to 31 mm/kV
Insulation typedry
Voltage classes of the standard range40.5, 72.5, 126, 245 kV
Versionswall bushing; combined bushing with current transformer

Part numbers

Show all part numbers (8)

STB 40.5/630, STB 40.5/3150, STB 72.5/630, STB 72.5/1600, STB 126/630, STB 126/2000, STB 245/630, STB 245/2000

Request a price and lead time

STB Wall Bushings for 40.5 to 252 kV and Currents up to 3150 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which currents are provided for the 126 kV class STB insulators?

The standard range includes the STB 126/630 at 630 A and the STB 126/2000 at 2000 A. For other conditions the manufacturer designs the version to the task.

Can a wall bushing be combined with a current transformer?

Yes, besides dry wall bushings the manufacturer also supplies combined bushing and current transformer versions for high voltage entries up to 252 kV.

What climatic conditions are the insulators designed for?

Ambient temperatures from -50 to +45 °C. The specific creepage distance of the external insulation is 25 to 31 mm/kV.