BGCT Board Mounted Generator Bushing Current Transformer, 600 V Insulation Class

The BGCT is a board mounted bushing current transformer for generators, used for relaying and metering. It is assembled on a mounting board, so it can be placed into the installation as a finished assembly.

Type
Bushing current transformer for generators, board mounted
Mounting
On the high voltage generator bushing or on IPB
Insulation class
600 V
Application
Relaying and metering

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The transformer is placed over the high voltage terminal bushing of a generator. As with other generator transformers of this type, it can be fitted over an isolated phase bus (IPB) in higher voltage systems, and it keeps its own 600 V insulation class. The mounting arrangement is made to suit any existing structure, and the unit is lighter than cast alternatives.

The BGCT is assembled on a mounting board, so it is put into position as a finished unit. The manufacturer offers pre-assembled packages of several cores. Coils can also be supplied separately, without the board, with terminals or flexible leads, where a mounting is already in place.

Each transformer is designed for the specific application and, where required, to match the characteristics of the transformer it replaces, so that protection does not need to be re-set. The core can have an air gap to limit residual magnetism and to influence behaviour in transient conditions. The windings can be provided with additional taps for testing. Conduit openings are threaded up to 1.5 in NPT, or non-threaded holes up to 52 mm are provided.

The rating factor is up to 1.0 at 55 °C ambient. Metering accuracy classes run from 0.15S to 0.6 under IEEE and from 0.2S to 0.5 under IEC, with burdens from B0.1 to B1.8 or from 2.5 to 45 VA. The dimensions and accuracy class depend on the transformation ratio, and only the single ratio (SR) version is offered.

Technical specifications

TypeBushing current transformer for generators, board mounted
MountingOn the high voltage generator bushing or on IPB
Insulation class600 V
ApplicationRelaying and metering
Rating factorUp to 1.0 at 55 °C
Accuracy class (IEEE)0.15S to 0.6
Accuracy class (IEC)0.2S to 0.5
BurdensB0.1 to B1.8 / 2.5 to 45 VA
RatioSingle ratio (SR) only
Supply formOn board, multi-core packages or separate coils
Coil leads without boardTerminals or flexible leads
Conduit openingsThreaded 1.5 in NPT, or holes up to 52 mm

Request a price and lead time

BGCT Board Mounted Generator Bushing Current Transformer, 600 V Insulation Class. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the BGCT differ from the encapsulated EGCT?

The BGCT is assembled on a mounting board, while the EGCT is encapsulated. Coils of the BGCT can also be supplied without the board.

Can only the coils be ordered?

Yes, the coils are supplied without the board, with terminals or flexible leads.

Which accuracy classes are available?

From 0.15S to 0.6 under IEEE and from 0.2S to 0.5 under IEC. The achievable class depends on the transformation ratio.