
SBCT Outdoor Mounted Slip-Over Bushing Current Transformer, Encapsulated
The SBCT is an encapsulated slip-over current transformer for outdoor mounting on the bushings of power transformers, high voltage circuit breakers and cable terminations. Versions with earthing screens and mounting kits are available for specific equipment.
- Type
- Encapsulated slip-over bushing current transformer
- Mounting
- Outdoors over a transformer bushing, HV breaker bushing or cable termination
- Application
- Relaying and metering
- Rating factor
- Up to 5.0 at 30 °C
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SBCT is fitted externally over the high voltage bushing of a power transformer or circuit breaker, or over a cable termination, without dismantling the equipment. This arrangement is used when a current transformer for protection or metering needs to be added or replaced on equipment already in service. The manufacturer makes special mounting arrangements for each cast housing to suit the specific bushing, which simplifies installation.
The housing is cast, in an ANSI 70 Sky Grey resin system. Each unit is designed for its application and, where needed, to repeat the characteristics of the transformer it replaces. Dual-core versions are available, with identical or different core parameters and 3 kV insulation between the coils.
The core can have an air gap to limit residual magnetism and to influence behaviour in transient conditions. Air core linear couplers are also available. The windings are supplied as single ratio (SR), dual ratio (DR) or multi ratio (MR). Conduit openings are threaded up to 1.5 in NPT, or non-threaded holes up to 52 mm are provided.
The rating factor is up to 5.0 at an ambient temperature of 30 °C. Accuracy classes run from 0.15S to 2.4 and from 0.2S to 5.0, with burdens from B0.1 to B1.8 or from 2.5 to 45 VA. The dimensions and accuracy class depend on the transformation ratio.
For selection, drawings or the dimensions of the bushing or cable termination at the installation point are required, along with the primary current, the winding arrangement, accuracy classes, burdens and whether an earthing screen is needed. Mounting kits and earthing screens are made for the specific bushing.
Technical specifications
| Type | Encapsulated slip-over bushing current transformer |
|---|---|
| Mounting | Outdoors over a transformer bushing, HV breaker bushing or cable termination |
| Application | Relaying and metering |
| Rating factor | Up to 5.0 at 30 °C |
| Accuracy class | 0.15S to 2.4 / 0.2S to 5.0 |
| Burdens | B0.1 to B1.8 / 2.5 to 45 VA |
| Windings | SR, DR or MR |
| Dual-core version | Insulation between coils 3 kV |
| Housing | ANSI 70 resin, Sky Grey |
| Options | Earthing screens, mounting kits, air core linear couplers |
| Conduit openings | Threaded 1.5 in NPT, or holes up to 52 mm |
Request a price and lead time
SBCT Outdoor Mounted Slip-Over Bushing Current Transformer, Encapsulated. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the SBCT be fitted without dismantling the transformer?
Yes, it is fitted externally over the bushing or cable termination, and a mounting kit is made for the specific bushing.
Is a dual-core version available?
Yes, with identical or different core parameters and 3 kV insulation between the coils.
Which winding arrangements are available?
Single ratio (SR), dual ratio (DR) or multi ratio (MR).
Similar equipment from other manufacturers






