EGCT Encapsulated Generator Bushing Current Transformer, 600 V Insulation Class
The EGCT is an encapsulated bushing current transformer that fits over the high voltage terminal bushing of a generator. The encapsulation protects the windings in harsh environments and under demanding operating conditions, and the unit is used for relaying and metering.
- Type
- Encapsulated bushing current transformer for generators
- Mounting
- On the high voltage generator bushing or on IPB
- Insulation class
- 600 V
- Application
- Relaying and metering
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The transformer is mounted over the high voltage terminal bushing of a synchronous power station generator. It can also be fitted over an isolated phase bus (IPB) in higher voltage systems, where the transformer keeps its own 600 V insulation class and the bus isolates it from the primary voltage. Each unit is engineered for the specific application and fitting position, and it is lighter than cast alternatives.
The windings and core are encapsulated, so the EGCT is chosen for installations where the transformer is exposed to weather or operates in harsh conditions. The housing is Sky Grey (ANSI 70). Threaded conduit openings up to 1.5 in NPT, or non-threaded holes up to 52 mm, are provided for cable entry.
The core can have an air gap to limit residual magnetism and to improve behaviour during transient conditions. Windings can be provided with additional taps for testing where required. The design can be matched to the characteristics of the transformer it replaces.
The rating factor is up to 1.0 at an ambient temperature of 55 °C. Metering accuracy classes run from 0.15S to 0.6 under IEEE and from 0.2S to 0.5 under IEC, with burdens from B0.1 to B1.8 or from 2.5 to 45 VA. The achievable dimensions and accuracy class depend on the transformation ratio, and the unit is available in single ratio (SR) only. To order, provide the drawings of the generator bushing or isolated phase bus, the rated primary current, the number and purpose of windings, the required accuracy classes and burdens, and the data of the transformer being replaced.
Technical specifications
| Type | Encapsulated bushing current transformer for generators |
|---|---|
| Mounting | On the high voltage generator bushing or on IPB |
| Insulation class | 600 V |
| Application | Relaying and metering |
| Rating factor | Up to 1.0 at 55 °C |
| Accuracy class (IEEE) | 0.15S to 0.6 |
| Accuracy class (IEC) | 0.2S to 0.5 |
| Burdens | B0.1 to B1.8 / 2.5 to 45 VA |
| Ratio | Single ratio (SR) only |
| Core | Air gap (optional) |
| Conduit openings | Threaded 1.5 in NPT, or holes up to 52 mm |
| Housing colour | Sky Grey (ANSI 70) |
Request a price and lead time
EGCT Encapsulated Generator Bushing Current Transformer, 600 V Insulation Class. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the EGCT be fitted to a bus with a voltage above 600 V?
Yes, on an isolated phase bus (IPB) the transformer keeps its 600 V insulation class, as the bus isolates it from the primary voltage.
Can it replace an existing transformer?
The design can be matched to the characteristics of the existing transformer, for which its nameplate data are needed.
Is a multi-ratio version available?
No, the design is available in single ratio (SR) only.