DURESCA DM / DMI / DM2I RIP wall bushings 36–300 kV

DURESCA DM, DMI and DM2I dry wall and roof bushings with RIP insulation for 36–300 kV AC and up to 200 kV DC, rated current 630–6300 A. There is no oil in the design. The bushings are installed at substations, including SVC/STATCOM and HVDC installations.

Rated voltage
36–300 kV AC, up to 200 kV DC
Rated current
630–6300 A
Insulation
RIP, condenser type with graded field control
Versions
indoor/indoor (DM), indoor/outdoor (DMI), outdoor/outdoor (DM2I)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The RIP insulation is of the condenser type with graded field control. The DM version is installed indoors on both sides, DMI is used for passage from indoors to outdoors, DM2I is designed for outdoor installation on both sides. The creepage distance is from 31 mm/kV. The bushing can be ordered with built-in current transformers. The design complies with IEC 60137, IEC 65700 and IEEE C57.19.00.

Technical specifications

Rated voltage36–300 kV AC, up to 200 kV DC
Rated current630–6300 A
InsulationRIP, condenser type with graded field control
Versionsindoor/indoor (DM), indoor/outdoor (DMI), outdoor/outdoor (DM2I)
Creepage distancefrom 31 mm/kV
StandardsIEC 60137, IEC 65700, IEEE C57.19.00

Request a price and lead time

DURESCA DM / DMI / DM2I RIP wall bushings 36–300 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8546 90 90 00
HS, 6 digits8546 90
CN (EU)8546 90 90
HTSUS (USA)8546 90 00 00
China customs tariff8546 90 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage are the DURESCA DM bushings designed for?

For 36–300 kV AC and up to 200 kV DC. Rated current is from 630 to 6300 A.

What insulation do the bushings have and do they contain oil?

RIP insulation, condenser type with graded field control, no oil. The creepage distance is from 31 mm/kV.

Which standards do the bushings comply with?

IEC 60137, IEC 65700 and IEEE C57.19.00.