International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

CEDASPE MV / BS / AS porcelain transformer bushings, 12–52 kV

CEDASPE porcelain medium-voltage bushings for 12–52 kV and 250–3150 A, for power and distribution transformers. The MV line is built to EN/DIN, while the BS and AS series meet the British and Australian standards.

Rated voltage
12–52 kV (BS from 1.1 kV)
Rated current
250–3150 A (BS up to 7500 A)
Creepage distance
290–1655 mm
Pollution level
P1–P4

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The BS version is available from 1.1 kV and for currents up to 7500 A. The creepage distance is 290–1655 mm, and the bushing is selected for pollution level P1–P4. The insulator is porcelain, and the design complies with EN 50180, EN 50243 and IEC 60137. The bushings are used on the MV side of power transformers and on distribution transformers.

Technical specifications

Rated voltage12–52 kV (BS from 1.1 kV)
Rated current250–3150 A (BS up to 7500 A)
Creepage distance290–1655 mm
Pollution levelP1–P4
StandardsEN 50180, EN 50243, IEC 60137
Insulatorporcelain

Replacement for

ИП-10, ИП-35 bushing insulators, transformer bushings 10–35 kV (general type)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

CEDASPE MV / BS / AS porcelain transformer bushings, 12–52 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8546 20 00 10
HS, 6 digits8546 20
CN (EU)8546 20 00
HTSUS (USA)8546 20 00 60
China customs tariff8546 20 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage and current range do the CEDASPE bushings cover?

The main line is rated for 12–52 kV and 250–3150 A. The BS version is available from 1.1 kV and for currents up to 7500 A.

Which pollution levels are the bushings suitable for?

The bushings are available for pollution levels P1–P4. The creepage distance is 290–1655 mm.

Which standards do the bushings meet?

The design is built to EN 50180, EN 50243 and IEC 60137. The BS and AS series are made to the British and Australian standards.