Autotransformers 50 to 3000 kVA, up to 36 kV, insulation class F or H

Single-phase and three-phase autotransformers from 50 to 3000 kVA for voltages up to 36 kV. Insulation class F or H, AN or AF cooling, aluminium or copper windings, and an IP00 or metal enclosure with a specified IP degree.

Rated power
50 to 3000 kVA
Rated voltage
up to 36 kV
Insulation class
F or H
Cooling
AN, AF

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

An autotransformer is a special transformer with a single winding that acts as both primary and secondary. Power systems use it in place of a transformer when voltage must be changed by a small ratio, for example 220 kV to 110 kV. It saves construction material and is easier to transport.

The rated (own) power of an autotransformer differs from its throughput power. At small ratios, such as halving the voltage, the ratio of power to unit size is better than for a transformer. Power autotransformers often run with a fixed ratio or with steps set by taps. In practice the most common are single-phase and three-phase units with taps for stepwise change of output voltage, and units with smooth output voltage regulation. Starting autotransformers are used when starting large induction motors, although this use is fairly limited.

Autotransformers must not be used to supply mining, medical or marine equipment.

The range covers 50 kVA to 3000 kVA at rated voltage up to 36 kV, with insulation class F or H and AN or AF cooling. Rated frequency is 50 or 60 Hz, maximum operating altitude is 1000 m above sea level, and ambient temperature is from -25 to 40 °C. The core is cold-rolled electrical steel with inorganic insulation, and the windings are aluminium or copper. The standard enclosure is IP00; a metal enclosure with a specified IP degree, such as IP20, IP21, IP23, IP31, IP33 or IP54, is made on request.

Standard fittings are thermal protection, PT100 sensors, HV terminals on the coils, flat busbar LV terminals, a rating plate, a wheeled chassis, lifting lugs and earthing terminals on the chassis. Optional items are anti-vibration pads, surge arresters, an enclosure, fans and connector bushings. Design, tests and tolerances follow PN EN 60076-1 and PN EN 60076-11, and units with other parameters are made by individual agreement.

Technical specifications

Rated power50 to 3000 kVA
Rated voltageup to 36 kV
Insulation classF or H
CoolingAN, AF
Max. operating altitude1000 m above sea level
Ambient temperature range-25 to 40 °C
Rated frequency50 or 60 Hz
Corecold-rolled electrical steel with inorganic insulation
Windingsaluminium or copper
Enclosurestandard IP00; metal enclosure with specified IP degree (IP20, IP21, IP23, IP31, IP33, IP54 etc.) on request
StandardsPN EN 60076-1, PN EN 60076-11

How it compares with similar models

ParameterAutotransformers 50 to 3000 kVA, up to 36 kV, insulation class F or HTTO C oil-immersed transformer with oil cooler, 6 to 15 MVA, up to 36 kVPower transformer 72.5–800 kV, 5 to 1000 MVAPower and oil-immersed transformers (up to 550 kV / 800 MVA; distribution up to 69 kV / 80 MVA)
CoolingAN, AFOFAF or KFAFONAN/ONAF, OFAF, ODAF, OFWF, ODWFONAN / ONAF / OD
Windingsaluminium or copperround or profiled wire in class H insulation, copper or aluminiumcopper, paper-insulated wire and transposed (CTC) conductoraluminium or copper
StandardsPN EN 60076-1, PN EN 60076-11PN EN 60076-1, PN EN 60076-6IEC, IEEEIEC 60076, ANSI/IEEE C57

Request a price and lead time

Autotransformers 50 to 3000 kVA, up to 36 kV, insulation class F or H. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What power and voltage ranges are covered?

Rated power is 50 kVA to 3000 kVA and rated voltage is up to 36 kV. Units with other parameters are made by individual agreement.

Which enclosure protection degrees are available?

The standard enclosure is IP00. A metal enclosure with a specified IP degree, for example IP20, IP21, IP23, IP31, IP33 or IP54, is made on request.

Where must autotransformers not be used?

They must not be used to supply mining, medical or marine equipment.