TTO C oil-immersed transformer with oil cooler, 6 to 15 MVA, up to 36 kV

The TTO C is an oil-immersed distribution transformer with an oil cooler. Rated 6 MVA to 15 MVA at MV up to 36 kV, OFAF or KFAF cooling, vector groups Dyn5 and Dyn11.

Type
TTO C oil-immersed transformer with oil cooler
Rated power
6 MVA to 15 MVA
Rated MV voltage
up to 36 kV
Rated LV voltage
400 V, 440 V, 800 V (other ratios possible)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TTO C is an oil-immersed power and distribution transformer. It converts medium voltage (MV) to low voltage (LV) or the reverse for delivery to end users. Oil-filled units are chosen where reliable operation and resistance to damage are required. The design gives very good cooling, and the oil keeps the unit relatively small next to a dry transformer of the same rating.

The range covers 6 MVA to 15 MVA at MV up to 36 kV. LV is 400 V, 440 V or 800 V, with other ratios possible. Cooling is OFAF or KFAF and vector groups are Dyn5 and Dyn11, with other groups on request. The insulation class follows PN-EN 60085.

The core is cold-rolled transformer steel with inorganic insulation. Windings are round or profiled wire in class H insulation, copper or aluminium. The tank carries an oil cooler, is made of powder-coated steel sheet to the C4 or C5 anti-corrosion system, and stands on an undercarriage with wheels that can be set to the direction of travel.

Standard equipment: porcelain HV bushings to DIN 42531 or EN 50180:2010 or connector bushings, porcelain LV bushings to DIN 42531 or EN 50180:2010, oil level indicator, Buchholz relay, drain valve to EN 50216-4 or DIN 42551, earthing terminals on the undercarriage, wheels adjustable for longitudinal and transverse travel, rating plate, dehydrating breather, contact thermometer, conservator with oil drain and filler, oil filler on the cover, lifting lugs, off-circuit tap changer, oil cooler with pump (sized to the rating), pressure relief valve and a protection box. The finish is RAL 7033. Options are a 7-position off-circuit tap changer, surge arresters and vibration pads.

The manufacturer also builds oil-immersed transformers with an on-load tap changer in the cooler version. Altitude is limited to 1000 m above sea level, ambient temperature is -25 to 40 °C and frequency is 50 Hz or 60 Hz. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6.

Technical specifications

TypeTTO C oil-immersed transformer with oil cooler
Rated power6 MVA to 15 MVA
Rated MV voltageup to 36 kV
Rated LV voltage400 V, 440 V, 800 V (other ratios possible)
CoolingOFAF or KFAF
Insulation classto PN-EN 60085
Vector groupsDyn5, Dyn11 (other groups possible)
Corecold-rolled transformer steel with inorganic insulation
Windingsround or profiled wire in class H insulation, copper or aluminium
Tankwith oil cooler, powder coated with C4 or C5 anti-corrosion system, wheeled undercarriage
Rated frequency50 Hz or 60 Hz
Altitudeup to 1000 m above sea level
Ambient temperature-25 to 40 °C
StandardsPN EN 60076-1, PN EN 60076-6

How it compares with similar models

ParameterTTO C oil-immersed transformer with oil cooler, 6 to 15 MVA, up to 36 kVMedium power oil transformer HV/MV or MV/MV, 6.3–100 MVA, up to 145 kVAutotransformers 50 to 3000 kVA, up to 36 kV, insulation class F or HPower transformer 72.5–800 kV, 5 to 1000 MVA
Rated power6 MVA to 15 MVAfrom 6.3 MVA up to 100 MVA50 to 3000 kVA—
CoolingOFAF or KFAFRadiators with throttle valvesAN, AFONAN/ONAF, OFAF, ODAF, OFWF, ODWF
Corecold-rolled transformer steel with inorganic insulationSheet steel, low no-load losses and low noisecold-rolled electrical steel with inorganic insulation—
Windingsround or profiled wire in class H insulation, copper or aluminiumElectrolytic copper, paper and enamel insulationaluminium or coppercopper, paper-insulated wire and transposed (CTC) conductor
StandardsPN EN 60076-1, PN EN 60076-6—PN EN 60076-1, PN EN 60076-11IEC, IEEE

Request a price and lead time

TTO C oil-immersed transformer with oil cooler, 6 to 15 MVA, up to 36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What power and voltage range does the TTO C cover?

6 MVA to 15 MVA, MV up to 36 kV and LV of 400 V, 440 V or 800 V, with other ratios possible.

What cooling and vector groups are offered?

OFAF or KFAF cooling with Dyn5 and Dyn11, and other groups on request.

Is an on-load tap changer version available?

Yes, the manufacturer builds oil-immersed transformers with an on-load tap changer in the cooler version. The standard fit is an off-circuit tap changer.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides