International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Medium power oil transformer HV/MV or MV/MV, 6.3–100 MVA, up to 145 kV

Medium power oil transformers in HV/MV or MV/MV configuration, from 6.3 MVA up to 100 MVA and voltage up to 145 kV. On-load or off-load tap changers and radiators fitted with throttle valves.

Type
Medium power oil transformer
Configuration
HV/MV or MV/MV
Rated power
from 6.3 MVA up to 100 MVA
Voltage
up to 145 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These medium power oil transformers are designed in HV/MV or MV/MV configuration, from 6.3 MVA up to 100 MVA, for voltages up to 145 kV. Units to a customer's special requirements can also be designed and produced. All transformers are manufactured in accordance with applicable standards.

The tanks are designed so that they can be lifted with hydraulic lifts and overhead cranes. The cores are made of high-quality sheet steel, giving low no-load losses and low noise in operation. Windings are electrolytic copper insulated with paper and enamel, using single, multiple and CTC technology wires.

According to the customer's requirements, the tap changers fitted can be on-load (oil and vacuum) or off-load. The transformers have radiators mounted with throttle valves.

Anti-corrosion protection consists of hot-dip galvanising and/or painting with water-based, epoxy and polyurethane paints. The transformers are designed for continuous operation, and load conditions follow the current IEC standard. In the standard version they are intended for operation in open spaces or in chambers with a moderate climate.

A group of engineers provides technical support. Measurements can be made on the transformers at the installation site and in the manufacturer's factory, together with a range of oil tests: dissolved gas amount and composition by gas chromatography (DGA), water content by the Karl Fischer method, breakdown voltage, resistivity, dielectric loss factor, acid number and flash point, and polychlorinated biphenyl (PCB) content.

Technical specifications

TypeMedium power oil transformer
ConfigurationHV/MV or MV/MV
Rated powerfrom 6.3 MVA up to 100 MVA
Voltageup to 145 kV
CoreSheet steel, low no-load losses and low noise
WindingsElectrolytic copper, paper and enamel insulation
Wire typeSingle, multiple, CTC
Tap changerOn-load (oil, vacuum) or off-load
CoolingRadiators with throttle valves
Anti-corrosion protectionHot-dip galvanising and/or water-based, epoxy, polyurethane paints
Load conditionsIn accordance with the current IEC standard
Operating conditionsOpen spaces or chambers with a moderate climate

How it compares with similar models

ParameterMedium power oil transformer HV/MV or MV/MV, 6.3–100 MVA, up to 145 kVTTO C oil-immersed transformer with oil cooler, 6 to 15 MVA, up to 36 kVPower transformer 72.5–800 kV, 5 to 1000 MVAMinera MP medium-power oil-immersed power transformer up to 100 MVA
WindingsElectrolytic copper, paper and enamel insulationround or profiled wire in class H insulation, copper or aluminiumcopper, paper-insulated wire and transposed (CTC) conductor—
CoolingRadiators with throttle valvesOFAF or KFAFONAN/ONAF, OFAF, ODAF, OFWF, ODWF—

Request a price and lead time

Medium power oil transformer HV/MV or MV/MV, 6.3–100 MVA, up to 145 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What power and voltage range do these transformers cover?

From 6.3 MVA up to 100 MVA and voltage up to 145 kV, in HV/MV or MV/MV configuration.

Which tap changers can be fitted?

According to the customer's requirements, on-load tap changers (oil or vacuum) or off-load tap changers.

Which oil tests are available?

Dissolved gas analysis by gas chromatography (DGA), Karl Fischer water content, breakdown voltage, resistivity, dielectric loss factor, acid number, flash point and PCB content.