QY 110–330 kV traction transformers and autotransformers for 27.5 kV electrified railways

QY are traction transformers of 110, 220 and 330 kV and autotransformers for substations of 27.5 kV AC railways. The 31.5 MVA models supply high-speed and heavy-haul lines with the AT system or direct feeding.

330 kV
QYD-31500/330: 31.5/20/20 MVA, (330 ±4×2.5 %)/2×27.5 kV, AT system
220 kV
QYS-(31500+31500)/220: Vx connection, 2×27.5 kV, AT system
110 kV
QYS-(31500+31500)/110: Vv connection, (110 ±4×2.5 %)/27.5 kV, direct feeding
AT autotransformer
QYOD-20000/2×27.5: 20 MVA, 2×27.5/27.5 kV, 0.45 Ohm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Traction transformers are installed at substations of 27.5 kV AC electrified railways, on high-speed main lines as well as heavy-haul lines. The traction load has a high harmonic content, a distorted waveform, sharp fluctuations and frequent short circuits in the contact network, and the design is calculated for this duty. The manufacturer built the industry's first 330 kV traction transformer for the autotransformer (AT) feeding system on the Zhengzhou–Xi'an line and has supplied equipment for the Xi'an–Yan'an, Baotou–Yinchuan, Zhongwei–Lanzhou and other lines.

The QYD-31500/330 works at traction substations of high-speed lines with the AT system. On the 330 kV side ((330 ±4×2.5 %) kV) it takes three-phase supply through a three-phase transformer or two single-phase ones in a Vx connection. On the lower-voltage side there are two independent 2×27.5 kV outputs with separate voltages and ratings, one for each direction of traffic. The rating is 31.5/20/20 MVA, short-circuit voltage 10.5 %, cooling ONAN, no-load loss 57.4 kW and short-circuit loss below 208 kW. The oil temperature rise is 50 K and that of the hottest winding spot 68 K. Full insulation withstands frequent short circuits; per the manufacturer, the HV insulation levels Um/SI/LI/LIC/AC are 363/950/1175/1300/510 kV and the LV levels Um/LI/LIC/AC are 31.5/200/220/85 kV.

The QYS-(31500+31500)/220, with an internal three-phase Vx connection, is intended for 220 kV substations with the AT system. It delivers the standard 2×27.5 kV, has low losses and intelligent condition monitoring. The 110 kV QYS-(31500+31500)/110 with a Vv connection works in direct feeding systems, including those with a return wire. Low traction impedance and small voltage drops allow long sections to be supplied, and the simple scheme lowers costs. Short-circuit voltage is 8.4 %, no-load loss 47.2 kW and short-circuit loss 208 kW.

The traction autotransformer QYOD-20000/2×27.5, rated 20 MVA (2×27.5/27.5 kV, impedance 0.45 Ohm), is installed at autotransformer posts of the contact network on high-speed and heavy-haul lines. It has high power utilisation, low losses and noise, resistance to overvoltages and little effect on communication lines. The unit works at high altitude, at low and high temperatures and in salt fog.

Technical specifications

330 kVQYD-31500/330: 31.5/20/20 MVA, (330 ±4×2.5 %)/2×27.5 kV, AT system
220 kVQYS-(31500+31500)/220: Vx connection, 2×27.5 kV, AT system
110 kVQYS-(31500+31500)/110: Vv connection, (110 ±4×2.5 %)/27.5 kV, direct feeding
AT autotransformerQYOD-20000/2×27.5: 20 MVA, 2×27.5/27.5 kV, 0.45 Ohm
Losses (330 kV)no-load 57.4 kW, short-circuit <208 kW
CoolingONAN
ReferencesZhengzhou–Xi'an, Xi'an–Yan'an, Baotou–Yinchuan, Zhongwei–Lanzhou

Replacement for

ТДТНЖ-25000/110, ТДТНЖ-40000/110, ТДТНЖ-40000/220, ТМЖ-400/27,5; Scott/V connection has no direct equivalent

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

QY 110–330 kV traction transformers and autotransformers for 27.5 kV electrified railways. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 23 00
HTSUS (USA)8504 23 00 80
China customs tariff8504 23 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which feeding schemes do the traction transformers support?

The QYD-31500/330 and QYS-(31500+31500)/220 work in the AT system with 2×27.5 kV outputs. The QYS-(31500+31500)/110 with a Vv connection is intended for direct feeding, including with a return wire.

What are the losses of the QYD-31500/330?

No-load loss 57.4 kW, short-circuit loss below 208 kW. Short-circuit voltage 10.5 %, ONAN cooling.

Where is the autotransformer QYOD-20000/2×27.5 installed?

At autotransformer posts of the contact network on high-speed and heavy-haul lines. Rating 20 MVA, voltages 2×27.5/27.5 kV, impedance 0.45 Ohm.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides