ВЛ-81М (VL-81M) compact three-circuit time relay, 0.1 s - 99 h

The ВЛ-81М (VL-81M) holds three independent circuits, each with its own setting inside a sub-range. Delays run from 0.1 s to 99 h, two supply versions (18-100 V and 88-264 V) are offered, and the relay mounts on a DIN-35 rail or on a flat surface.

Delay range
0.1 s - 99 h
Number of circuits
3 independent
Supply voltage (versions)
DC/AC 50 Hz: 18-100 V or 88-264 V
Supply ripple (DC)
up to 10 %

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ВЛ-81М (VL-81M) is a compact three-circuit time relay that switches electrical circuits with preset time delays. It is fitted in automation schemes as a component part, and a single relay covers settings from 0.1 s to 99 h.

Three circuits work independently, and each can be given the required setting within one sub-range, which is selected with a switch on the front panel. Timing begins in all three circuits when the supply voltage is applied. As soon as the delay of a circuit has elapsed, its output relay operates and its LED lights up. A green LED indicates supply and three red LEDs indicate the output relays.

Two supply versions exist for DC, rectified and 50 Hz AC voltage: 18-100 V and 88-264 V. Supply ripple on DC relays may reach 10 %. Consumption is up to 5 VA (W). The additional error from temperature is up to 0.1 % per 1 °C. The mean basic error of the delay does not exceed ± (0.5 + 0.15 TMAX/T) %, where TMAX is the maximum setting of the sub-range and T is the setting at which the error is determined.

Each circuit has one changeover contact. Switching voltage is 12-250 V DC and 12-400 V AC, with 30 W (DC-11) and 400 VA (AC-22). Protection degree is IP30 for the housing and IP20 for the terminal block. Dimensions are up to 70x90x65 mm and weight up to 0.5 kg; the relay is fixed on a DIN-35 rail or on a flat surface.

The climatic version is У category 3 to GOST15150-69. Operating temperature is -40 to +55 °C up to 1000 m, with relative humidity up to 93 % at 25 °C. Supply-line impulse interference up to twice the rated voltage and up to 10 µs long is tolerated. Mechanical resistance corresponds to group M7 of GOST 17516.1-90.

Technical specifications

Delay range0.1 s - 99 h
Number of circuits3 independent
Supply voltage (versions)DC/AC 50 Hz: 18-100 V or 88-264 V
Supply ripple (DC)up to 10 %
Power consumptionup to 5 VA (W)
Additional temperature errorup to 0.1 % per 1 °C
Output contacts1 changeover per circuit
Switching voltage DC12-250 V
Switching voltage AC12-400 V
Switching power30 W (DC-11); 400 VA (AC-22)
Operating temperature-40...+55 °С
Relative humidity93 % at 25 °С
Protection degree housing / terminal blockIP30 / IP20
Dimensionsup to 70x90x65 mm
Weightup to 0.5 kg
Mountingon a DIN-35 rail or a flat surface

Part numbers

Show all part numbers (1)

ВЛ-81М

How it compares with similar models

ParameterВЛ-81М (VL-81M) compact three-circuit time relay, 0.1 s - 99 hВЛ-100М (VL-100M) microprocessor three-circuit time relay with digital display, 0.05 s - 99.9 minВЛ-85 three-channel microprocessor time relay, 0.1 s to 9.99 h delay rangeВЛ-159М-4 (VL-159M-4) multifunction time relay, 8 functions, pulse counter, 0.1 s - 9999 min
Power consumptionup to 5 VA (W)up to 7 VA7 VA max.up to 5 VA (W)
Output contacts1 changeover per circuit3 changeover (1 + 1 + 1)1п + 1п + 1п2 changeover
Switching power30 W (DC-11); 400 VA (AC-22)30 W DC, 400 VA AC30 W (DC); 400 VA (AC)—
Dimensionsup to 70x90x65 mm53 × 90 × 65 mm53 × 90 × 65 mm70x90x65 mm
Weightup to 0.5 kgup to 0.25 kg0.25 kg max.up to 0.25 kg
Mountingon a DIN-35 rail or a flat surfaceon a DIN-35 railDIN-35 rail—

Request a price and lead time

ВЛ-81М (VL-81M) compact three-circuit time relay, 0.1 s - 99 h. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many circuits does the ВЛ-81М have and how are they set?

Three independent circuits; each is set inside a sub-range that a switch on the front panel selects.

Which supply versions are available?

Two: 18-100 V and 88-264 V, for DC, rectified and 50 Hz AC voltage.

How is the relay fixed?

On a DIN-35 rail or on a flat surface; protection degree is IP30 for the housing and IP20 for the terminals.