UKN-01M and UKN-01M2 voltage transformer circuit monitoring relays

The UKN-01M checks the voltage circuits of measuring voltage transformer windings connected in open delta, and the UKN-01M2 checks that those windings are continuous. Input is 100 V, measuring range 0.02–9.0 V, and the supply is = 220 / ~220 V.

Versions
UKN-01M (open delta), UKN-01M2 (winding continuity)
Auxiliary supply voltage
= 220; ~220 V
Supply voltage limits
90-250 V
Nominal input signal voltage, 50 Hz
100 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The UKN-01M and UKN-01M2 watch the secondary circuits of measuring voltage transformers continuously and automatically. The UKN-01M monitors the integrity of windings connected in open delta, while the UKN-01M2 monitors the continuity of the windings themselves.

Each relay measures the active value of the input signal and extracts its 150 Hz component, and it also measures the 50 Hz component. When the voltage rises above or falls below a setting, the relay operates after the set time delay and records the voltage value at the moment of operation. The input signal value is displayed.

Nominal input signal is 100 V at 50 Hz and the measured voltage range is 0.02–9.0 V. Overvoltage settings run 0.3–9.0 V on the UKN-01M and 0.05–9.0 V on the UKN-01M2, adjustable in 0.01 V steps. Operating time is set between 0.1 and 9.9 s. The reset ratio after the measured voltage falls below the setting is 0.9 – 0.95.

Auxiliary supply is = 220 / ~220 V within limits of 90-250 V. At Uin = 100 V the monitored circuit draws up to 1.0 VA and the supply circuit up to 5.0 VA. Ambient temperature is -20...+55 °C and relative humidity at 25 °C is up to 80 %. Mass is up to 0.7 kg.

Install the relays on panels and control boards of relay rooms, in relay cabinets and in КРУ compartments.

Technical specifications

VersionsUKN-01M (open delta), UKN-01M2 (winding continuity)
Auxiliary supply voltage= 220; ~220 V
Supply voltage limits90-250 V
Nominal input signal voltage, 50 Hz100 V
Measured voltage range0.02–9.0 V
Overvoltage setting range UKN-01M0.3–9.0 V
Overvoltage setting range UKN-01M20.05–9.0 V
Voltage setting resolution0.01 V
Operating time setting range0.1 - 9.9 s
Power drawn by the monitored circuit at Uin = 100 Vmax 1.0 VA
Power drawn by the supply circuitmax 5.0 VA
Reset ratio0.9 – 0.95
Ambient temperature-20...+55 °C
Relative humidity at 25 °Cmax 80 %
Massmax 0.7 kg

Part numbers

Show all part numbers (2)

УКН-01М, УКН-01М2

European equivalents

CAPDIS-M + CAPDIS-4, voltage monitoring module and amplifier replacing voltage transformers with capacitive sensors

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

UKN-01M and UKN-01M2 voltage transformer circuit monitoring relays. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the UKN-01M and UKN-01M2 differ?

The UKN-01M monitors voltage circuits of transformer windings connected in open delta; the UKN-01M2 monitors continuity of those windings.

What auxiliary supply is needed?

= 220 / ~220 V within 90-250 V, drawing up to 5.0 VA from the supply circuit.

What are the setting ranges?

Voltage 0.3–9.0 V (UKN-01M) or 0.05–9.0 V (UKN-01M2) in 0.01 V steps, and operating time 0.1 - 9.9 s.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides