International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PE40, PE40-M instantaneous intermediate relay, 24-230 V DC and 24-400 V AC

ПЕ40 and ПЕ40-М are electromagnetic intermediate relays with no intentional delay. They switch DC circuits at 24-230 V and AC circuits at 24-400 V, 50 and 60 Hz, operate in up to 0.03 s and carry up to 8 contact groups.

Rated circuit voltage, DC
24-230 V
Rated circuit voltage, AC
24-400 V, 50 and 60 Hz
Operate time
up to 0.03 s
Contact groups
up to 8

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ПЕ40 relay is a normal-speed instantaneous type for protection, control and automation schemes in power-engineering equipment. The load circuit is rated 24 to 230 V DC or 24 to 400 V AC at 50 and 60 Hz. Operate time is up to 0.03 s. The relay also drives the closing and tripping coils of vacuum and oil circuit breakers.

Contacts are arranged in up to 8 groups. ПЕ40 is the basic version, and ПЕ40-М adds a module under a transparent cover. Modules М1-М5 cover shunting, an RC circuit, indication and surge protection. Coil consumption is not more than 6 W on DC and not more than 10 VA on AC.

Minimum contact current is 0.02 A at 24 V and 0.01 A at 110 V and above. Test voltage for insulation is 2500 V between independent circuits and between circuits and case, 1000 V across open contacts and 550 V for coils. Insulation resistance is 20 MOhm cold and 6 MOhm heated. Mechanical life is not less than 500000 cycles, switching life not less than 100000 cycles.

The relay is built in versions У3 and Т3 for minus 40 to plus 55 °C and withstands vibration up to 15 Hz at 3g and 15 to 100 Hz at 1g. Protection is IP40 for the relay, IP30 for ПЕ40-10 with soldering lugs, IP10 for screw terminals and IP00 for soldering lugs. The case material withstands up to 650 °C and the terminal material up to 960 °C.

It follows ГОСТ 14254-96 and НП 306.2.141-2008 and is used at nuclear power plants (classes 3Н and 4Н). Mounting is on a DIN rail (extra module needed), by screw, or surface-mounted on a vertical plane. Wire cross-section is 0.12-1.5 mm² for soldering and 0.75-2.5 mm² for screw terminals.

Technical specifications

Rated circuit voltage, DC24-230 V
Rated circuit voltage, AC24-400 V, 50 and 60 Hz
Operate timeup to 0.03 s
Contact groupsup to 8
Minimum contact current0.02 A at 24 V; 0.01 A at 110 V and above
Coil power, DCnot more than 6 W
Coil power, ACnot more than 10 VA
Insulation test voltage, circuits to each other and to case2500 V
Insulation test voltage, open contacts1000 V
Insulation test voltage, coils550 V
Insulation resistance, cold / heated20 MOhm / 6 MOhm
Mechanical lifenot less than 500000 cycles
Switching lifenot less than 100000 cycles
Protection degreeIP40 (relay), IP30 (ПЕ40-10 with soldering lugs), IP10 (screw terminals), IP00 (soldering lugs)
Operating temperaturefrom minus 40 to plus 55 °C
Climatic versionsУ3, Т3
Vibrationup to 15 Hz at 3g; 15-100 Hz at 1g
Wire cross-section, soldering / screw0.12-1.5 mm² / 0.75-2.5 mm²

How it compares with similar models

ParameterPE40, PE40-M instantaneous intermediate relay, 24-230 V DC and 24-400 V ACPE41, PE41-M fast intermediate relay, 24-230 V DC and 24-400 V ACПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V ACПЕ42, ПЕ42-М non-delayed DC electromagnetic intermediate relay, operate time up to 0,03 s
Operate timeup to 0.03 sup to 0.011 s—up to 0,03 s
Minimum contact current0.02 A at 24 V; 0.01 A at 110 V and above0.02 A at 24 V; 0.01 A at 110 V and above0,02 A at 24 V; 0,01 A at 110 V and above0,02 A at 24 V; 0,01 A at 110 V and above
Protection degreeIP40 (relay), IP30 (ПЕ40-10 with soldering lugs), IP10 (screw terminals), IP00 (soldering lugs)IP40 (relay), IP10 (terminals)IP40 (relay), IP10 (screw terminals)IP40 (relay), IP10 (screw terminals)
Vibrationup to 15 Hz at 3g; 15-100 Hz at 1gup to 15 Hz at 3g; 15-100 Hz at 1gup to 15 Hz at 3g, 15 to 100 Hz at 1gup to 15 Hz at 3g, 15 to 100 Hz at 1g

European equivalents

Auxiliary, bistable and contactor relays for substations

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

PE40, PE40-M instantaneous intermediate relay, 24-230 V DC and 24-400 V AC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How fast does the ПЕ40 relay operate?

Operate time is up to 0.03 s, as it is an instantaneous relay of normal speed.

How many contact groups are available?

Up to 8 contact groups.

Which wire sizes can be connected?

0.12-1.5 mm² for soldering and 0.75-2.5 mm² for screw terminals.