ISOMETER® isoCHA425HV with coupling device AGH420-1/AGH421-1 for CCS and CHAdeMO DC charging stations
The ISOMETER® isoCHA425HV with a coupling device, AGH420-1 or AGH421-1, monitors insulation resistance in unearthed DC systems of 0…1000 V. It switches between CCS and CHAdeMO modes and has an electrically isolated Modbus RTU interface.
- Type
- Insulation monitoring device with coupling device
- Nominal system voltage Un
- DC 0…1000 V (CCS), DC 50…1000 V (CHAdeMO)
- Max. leakage capacitance (CHAdeMO)
- 1.6 μF per conductor
- Max. leakage capacitance (CCS)
- 20 μF
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A DC fast charging station needs its insulation watched before and during charging, and the isoCHA425HV does this for stations built to CHAdeMO or to the Combined Charging System (CCS). It measures insulation resistance RF. Nominal system voltage Un is DC 0…1000 V for CCS and DC 50…1000 V for CHAdeMO, in unearthed DC systems, with the AGH420-1 or AGH421-1 coupling device.
Both symmetrical and asymmetrical insulation faults are detected, and the display shows the fault location (DC+/DC-/balanced). The device is switchable between CCS and CHAdeMO. It also monitors system leakage capacitance Ce, the system voltages and undervoltage and overvoltage, and it can test the contactors in the charging station and in the vehicle.
Maximum system leakage capacitance is 1.6 μF per conductor for CHAdeMO and 20 μF for CCS. In CHAdeMO mode the response time is up to 1 s for RFU up to 100 kΩ, and up to 10 s for RFU from 100 kΩ to 2 MΩ or RFS up to 160 kΩ. In CCS mode it is up to 10 s for Ce up to 5 μF or RF up to 100 kΩ, with a detection limit of up to 2 MΩ.
Measuring voltage Um is ±45 V, measuring current Im is up to 400 μA and internal resistance Ri, Zi is at least 120 kΩ. Rated impulse voltage is 8 kV, rated insulation voltage 1000 V, overvoltage category III and pollution degree 3. Data goes out over an electrically isolated Modbus RTU interface (RS-485); a BMS interface and IsoData are also provided.
The unit is fitted on a DIN rail or with screws, using mounting clip B98060008 and mounting frame XM420 (B990994) for screw mounting. Operating temperature is -40 to +70 °C, transport -40 to +85 °C and storage -40 to +70 °C. Built-in components are IP30, terminals IP20, and weight is up to 150 g.
Technical specifications
| Type | Insulation monitoring device with coupling device |
|---|---|
| Nominal system voltage Un | DC 0…1000 V (CCS), DC 50…1000 V (CHAdeMO) |
| Max. leakage capacitance (CHAdeMO) | 1.6 μF per conductor |
| Max. leakage capacitance (CCS) | 20 μF |
| Response time (CCS) | ≤ 10 s |
| Detection limit (CCS) | up to 2 MΩ |
| Measuring voltage Um | ±45 V |
| Measuring current Im | ≤ 400 μA |
| Internal resistance Ri, Zi | ≥ 120 kΩ |
| Rated impulse voltage | 8 kV |
| Rated insulation voltage | 1000 V |
| Overvoltage category / pollution degree | III / 3 |
| Interface | Modbus RTU (RS-485) |
| Operating temperature | -40…+70 °C |
| Degree of protection (built-in / terminals) | IP30 / IP20 |
| Weight | ≤ 150 g |
Part numbers
Show all part numbers (4)
B71036396 (AGH420-1), B71036399 (AGH421-1), B98060008, B990994
How it compares with similar models
| Parameter | ISOMETER® isoCHA425HV with coupling device AGH420-1/AGH421-1 for CCS and CHAdeMO DC charging stations | ISOMETER® isoHV425 with AGH422 insulation monitoring device for IT systems up to AC/DC 1000 V | ISOMETER® IRDH275BM-7 with AGH675S-7 coupling devices, insulation monitoring up to 15.5 kV | ISOMETER® isoPV425 with AGH420 insulation monitoring device for AC/DC IT systems up to 690 V / 1000 V |
|---|---|---|---|---|
| Nominal system voltage Un | DC 0…1000 V (CCS), DC 50…1000 V (CHAdeMO) | AC/DC 0…1000 V | — | 3(N)AC, AC, AC/DC 0…690 V or DC 0…1000 V |
| Internal resistance Ri, Zi | ≥ 120 kΩ | ≥ 390 kΩ | — | ≥ 120 kΩ |
Request a price and lead time
ISOMETER® isoCHA425HV with coupling device AGH420-1/AGH421-1 for CCS and CHAdeMO DC charging stations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which charging standards does the isoCHA425HV cover?
DC stations to CCS (DC 0…1000 V) and CHAdeMO (DC 50…1000 V); the mode is switchable.
What system leakage capacitance is permitted?
1.6 μF per conductor for CHAdeMO and 20 μF for CCS.
Which interface carries the data?
An electrically isolated Modbus RTU (RS-485); a BMS interface and IsoData are also available.