International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

CC613 EV Charge Controller up to 80 A, Charging Mode 3, OCPP and ISO 15118

The CC613 manages an EV charging station to IEC 61851-1 (charging mode 3) up to 80 A. It integrates dynamic load management, PE monitoring and 6 mA DC fault current detection, supports OCPP, EEBUS and ISO 15118, and connects by Ethernet and 4G.

Standard
IEC 61851-1 (charging mode 3)
Maximum current
80 A
Protocols
OCPP 1.5, OCPP 1.6 (JSON, SOAP), EEBUS, ISO 15118 (PLC), Modbus TCP, Modbus RTU
Interfaces
Ethernet, 4G modem (LTE, UMTS, GSM), 3 USB (1 CONFIG, 2 Host), Control Pilot, Proximity Pilot, meter interface, 2-channel I/O extension

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The CC613 is an intelligent charge controller for electric vehicle charging stations, wallboxes and street light charging points. It handles the communication between the vehicle, the backend and the charging hardware to IEC 61851-1 (charging mode 3), with a maximum current of 80 A. The controller is VDE certified.

Protection is built in: PE monitoring, 6 mA DC fault current detection, which allows an RCD type A to be used, weld check detection and an integrated emergency opener. Dynamic load management (DLM) distributes power among the charging points.

Protocols are OCPP 1.5 and OCPP 1.6 (JSON, SOAP), EEBUS, ISO 15118 (PLC) for plug and charge, Modbus TCP and Modbus RTU. Interfaces are Ethernet, a 4G modem (LTE, UMTS, GSM), three USB ports (one CONFIG, two Host), Control Pilot, Proximity Pilot, a meter interface and a 2-channel I/O extension. Software is updated over USB, Ethernet or OTA. RFID modules, the DPM2x16FP display module and the CTBC17 measuring current transformer connect to the controller.

Four versions are listed. The CC613-ELM4PR-M4G (B94060020) has Modbus, Ethernet, RDC-M, PLC, a user interface, I/O extension and a 4G modem. The CC613-ELPR-M (B94060021) is the same without the 4G modem. The CC613-ELM4PR4G (B94060026) has Modbus, Ethernet, a user interface, I/O extension and a 4G modem, without RDC-M and PLC. The CC613-ELPR (B94060027) has the same functions without the 4G modem, RDC-M and PLC. The plugs are ordered separately as the Plug kit CC613 (B94060129).

Technical specifications

StandardIEC 61851-1 (charging mode 3)
Maximum current80 A
ProtocolsOCPP 1.5, OCPP 1.6 (JSON, SOAP), EEBUS, ISO 15118 (PLC), Modbus TCP, Modbus RTU
InterfacesEthernet, 4G modem (LTE, UMTS, GSM), 3 USB (1 CONFIG, 2 Host), Control Pilot, Proximity Pilot, meter interface, 2-channel I/O extension
MonitoringPE monitoring, 6 mA DC fault current detection, weld check detection, dynamic load management (DLM)
Emergency openerintegrated
Software updateUSB, Ethernet, OTA
CertificationVDE
VersionsCC613-ELM4PR-M4G, CC613-ELPR-M, CC613-ELM4PR4G, CC613-ELPR

Part numbers

Show all part numbers (4)

B94060020 (ELM4PR-M4G), B94060021 (ELPR-M), B94060026 (ELM4PR4G), B94060027 (ELPR)

How it compares with similar models

ParameterCC613 EV Charge Controller up to 80 A, Charging Mode 3, OCPP and ISO 15118ICC1324 PCB Charge Controller for AC Charging Stations, DLM, 6 mA DC DetectionICC1314 Compact PCB Charge Controller for AC Charging Stations up to 3x 32 AICC1624 All-In-One Charge Controller on One Board for AC Stations up to 22 kW
ProtocolsOCPP 1.5, OCPP 1.6 (JSON, SOAP), EEBUS, ISO 15118 (PLC), Modbus TCP, Modbus RTUModbus TCP, Modbus RTU, OCPP 1.6 (JSON), EEBUS, SMA SEMP, ISO 15118OCPP 1.6+ (JSON), Modbus TCP, EEBUS, ISO 15118OCPP 1.6-J, Modbus RTU, Modbus TCP, EEBUS, ISO 15118
InterfacesEthernet, 4G modem (LTE, UMTS, GSM), 3 USB (1 CONFIG, 2 Host), Control Pilot, Proximity Pilot, meter interface, 2-channel I/O extensionWiFi, Ethernet, 4G modem, USB, Micro-SIM, Control Pilot, Proximity Pilot4G modem, WiFi, 2 Ethernet, USB, Modbus meter, Control Pilot, Proximity Pilot2 x USB Type-A, 1 x USB Type-B, 4G (Cat 1), 2 Ethernet, WiFi, PLC

Request a price and lead time

CC613 EV Charge Controller up to 80 A, Charging Mode 3, OCPP and ISO 15118. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the CC613 versions differ?

The ELM4PR-M4G has RDC-M, PLC and a 4G modem, the ELPR-M is the same without 4G, the ELM4PR4G has 4G without RDC-M and PLC, and the ELPR has none of 4G, RDC-M and PLC.

Which backend protocols are supported?

OCPP 1.5 and OCPP 1.6 (JSON, SOAP), EEBUS and ISO 15118 (PLC), with Modbus TCP and Modbus RTU for local integration.

What earth fault protection is built in?

PE monitoring and 6 mA DC fault current detection, which allows an RCD type A to be used, plus weld check detection.