ICC1324 PCB Charge Controller for AC Charging Stations, DLM, 6 mA DC Detection
The ICC1324 is a 4th generation charge controller on a circuit board with an integrated power supply, for AC charging stations. It has patented 6 mA DC fault current detection, dynamic load management, ISO 15118 PLC, WiFi, Ethernet and a 4G modem.
- Supply voltage AC
- 230 V (184 V…264 V), 50 Hz
- Power consumption
- max. 12 W, typ. 6 W
- Rated voltage / pollution degree
- 250 V / 2
- Overvoltage category
- II (within terminal M), III (terminal M and all other terminals)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The ICC1324 is a 4th generation charge controller for EV applications in public, semi-public and private charging stations. It is built as a PCB with an integrated power supply for classic integration with standard components. It controls Type 1 and Type 2 socket-outlets and fixed cables for set-ups to IEC 61851-1 and IEC 62955.
Its functions are patented 6 mA DC fault current detection, dynamic load management (DLM) to distribute power among up to 250 vehicles, weld check, PE monitoring and ISO 15118 PLC for plug and charge. Software is updated over USB, Ethernet or OTA. Protocols are Modbus TCP, Modbus RTU, OCPP 1.6 (JSON), EEBUS, SMA SEMP and ISO 15118. Interfaces are WiFi, Ethernet, a 4G modem, USB, a Micro-SIM slot, Control Pilot and Proximity Pilot, two optocoupler inputs, two 12 V relay outputs and a switching contact for a contactor (AC 230 V / 4 A).
Five versions exist. The ICC1324-Connect Plus has a 4G modem (Cat 1), WiFi, PLC, 2 insulated inputs and 2 relay outputs of 12 V. The ICC1324-Connect has a 4G modem (Cat M1/NB1), no WiFi, PLC, 1 input and 1 output. The ICC1324-Connect SP has no 4G and no WiFi, PLC, 1 input and 1 output. The ICC1324-Home Plus has no 4G and no WiFi, PLC, 1 input and no relay output, and the ICC1324-Home has no 4G, WiFi or PLC, 1 input and no relay output.
Supply is AC 230 V (range 184 V…264 V) at 50 Hz, with power consumption of up to 12 W and typically 6 W. The RDC-M measuring range is 100 mA, the DC residual current threshold is 6 mA and the response tolerance is −50…0 %. Relay 1 is rated DC 24 V / 1 A and the contactor output AC 230 V / 4 A. The connection cable is up to 1.47 m long. Dimensions are 130 x 125 x 36 mm, the board is fixed flush with four M 2.5 screws (0.36 Nm) and the operating altitude is up to 2000 m AMSL.
Technical specifications
| Supply voltage AC | 230 V (184 V…264 V), 50 Hz |
|---|---|
| Power consumption | max. 12 W, typ. 6 W |
| Rated voltage / pollution degree | 250 V / 2 |
| Overvoltage category | II (within terminal M), III (terminal M and all other terminals) |
| Rated impulse voltage | 6 kV (terminal M and all other terminals), 2.5 kV (within terminal M) |
| Measuring range RDC-M | 100 mA |
| Residual current Idc | DC 6 mA (response tolerance −50…0 %) |
| Relay 1 | DC 24 V / DC 1 A |
| Contactor | AC 230 V / AC 4 A |
| Maximum connection cable length | ≤ 1.47 m |
| Protocols | Modbus TCP, Modbus RTU, OCPP 1.6 (JSON), EEBUS, SMA SEMP, ISO 15118 |
| Interfaces | WiFi, Ethernet, 4G modem, USB, Micro-SIM, Control Pilot, Proximity Pilot |
| Dynamic load management | up to 250 vehicles |
| Operating altitude | ≤ 2000 m AMSL |
| Dimensions | 130 x 125 x 36 mm |
Part numbers
Show all part numbers (5)
B94060080, B94060074, B94060078, B94060079, B94060077
How it compares with similar models
| Parameter | ICC1324 PCB Charge Controller for AC Charging Stations, DLM, 6 mA DC Detection | ICC1314 Compact PCB Charge Controller for AC Charging Stations up to 3x 32 A | ICC1624 All-In-One Charge Controller on One Board for AC Stations up to 22 kW | HMI140, HMI145 and HMI150 User Interface Modules for Charge Controllers |
|---|---|---|---|---|
| Power consumption | max. 12 W, typ. 6 W | max. 12 W, average 6 W | max. 17 W, average 6 W | — |
| Protocols | Modbus TCP, Modbus RTU, OCPP 1.6 (JSON), EEBUS, SMA SEMP, ISO 15118 | OCPP 1.6+ (JSON), Modbus TCP, EEBUS, ISO 15118 | OCPP 1.6-J, Modbus RTU, Modbus TCP, EEBUS, ISO 15118 | — |
| Interfaces | WiFi, Ethernet, 4G modem, USB, Micro-SIM, Control Pilot, Proximity Pilot | 4G modem, WiFi, 2 Ethernet, USB, Modbus meter, Control Pilot, Proximity Pilot | 2 x USB Type-A, 1 x USB Type-B, 4G (Cat 1), 2 Ethernet, WiFi, PLC | — |
| Operating altitude | ≤ 2000 m AMSL | ≤ 2000 m AMSL | — | ≤ 2000 m |
| Dimensions | 130 x 125 x 36 mm | 120 x 100 mm | 220 x 180 mm | 80 mm x 100 mm |
Request a price and lead time
ICC1324 PCB Charge Controller for AC Charging Stations, DLM, 6 mA DC Detection. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do the ICC1324 versions differ?
Connect Plus has 4G Cat 1, WiFi and PLC; Connect has 4G Cat M1/NB1 without WiFi; Connect SP and Home Plus have PLC without 4G; Home has no 4G, WiFi or PLC.
How many vehicles does dynamic load management cover?
Up to 250 vehicles, with power distributed among them by the DLM function.
What supply does the controller need?
AC 230 V within 184 V…264 V at 50 Hz, with power consumption of up to 12 W and typically 6 W.
Similar equipment from other manufacturers