EH-d32 low-housing transformer station up to 6.6 kV
Low-housing transformer station for voltages up to 6.6 kV, used to supply and control devices of mining machinery. Rated power up to 1030 kVA, primary voltage up to 6600 V, secondary up to 4160 V, designed to Directive 2014/34/EU (ATEX).
- Rated power
- up to 1030 kVA
- Rated primary voltage
- up to 6600 V
- Rated secondary voltage
- up to 4160 V
- Rated frequency
- 50, 60 Hz
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The EH-d32 is a transformer station for voltages up to 6.6 kV with a low housing. It supplies power to, and controls, devices of mining machinery and equipment, and it can be installed in underground workings of non-methane and methane mines. The design was developed to meet Directive 2014/34/EU (ATEX).
The electrical safety measures and the control and cooperation system with technological interlocks, which uses intrinsically safe circuits, allow safe cooperation with the power supply devices of mining machines.
Key features are the low housing, remote or local control and a compact construction. The number of three-phase main outlets and of three-phase and single-phase auxiliary outlets up to 230 V depends on the configuration, and the manufacturer shows an example configuration diagram.
Main data: rated power up to 1030 kVA, primary voltage up to 6600 V, secondary voltage up to 4160 V, frequency 50 or 60 Hz, connection groups Dyn5, Yyn0, Dyn5yn5 and Yyn0yn0 (other groups are possible), rated current of a single main outlet up to 400 A and weight up to 8050 kg. Appearance, dimensions and description are given in the manufacturer's documentation.
Technical specifications
| Rated power | up to 1030 kVA |
|---|---|
| Rated primary voltage | up to 6600 V |
| Rated secondary voltage | up to 4160 V |
| Rated frequency | 50, 60 Hz |
| Group of connections | Dyn5, Yyn0, Dyn5yn5, Yyn0yn0 (other groups possible) |
| Number of three-phase main outlets | depends on the configuration |
| Number of three-phase auxiliary outlets up to 230 V | depends on the configuration |
| Number of single-phase auxiliary outlets up to 230 V | depends on the configuration |
| Rated current of a single main outlet | up to 400 A |
| Device weight | up to 8050 kg |
| Directive | 2014/34/EU (ATEX) |
How it compares with similar models
| Parameter | EH-d32 low-housing transformer station up to 6.6 kV | EH-d30(d31) transformer station up to 6.6 kV for mining machinery | EH-d09 transformer assembly up to 1.1 kV for mining machinery | Smart CSS i1000 |
|---|---|---|---|---|
| Rated power | up to 1030 kVA | up to 2600 kVA | up to 10 kVA | — |
| Number of single-phase auxiliary outlets up to 230 V | depends on the configuration | depends on the configuration | up to 6 | — |
| Device weight | up to 8050 kg | up to 11800 kg | up to 450 kg | — |
Request a price and lead time
EH-d32 low-housing transformer station up to 6.6 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What distinguishes the EH-d32 in construction?
It has a low, compact housing, and it can be controlled remotely or locally.
What are the main ratings?
Rated power up to 1030 kVA, primary voltage up to 6600 V, secondary up to 4160 V, frequency 50 or 60 Hz and up to 400 A per main outlet.
How heavy is the station?
Up to 8050 kg, depending on the configuration.
Other analogues
European analogues of КТПВ from other manufacturers and series.





Similar equipment from other manufacturers