EH-d30(d31) transformer station up to 6.6 kV for mining machinery
Transformer station for voltages up to 6.6 kV that supplies and controls devices of mining machinery. Rated power up to 2600 kVA, primary voltage up to 6600 V, secondary up to 4160 V, designed to Directive 2014/34/EU (ATEX).
- Rated power
- up to 2600 kVA
- Rated primary voltage
- up to 6600 V
- Rated secondary voltage
- up to 4160 V
- Rated frequency
- 50, 60 Hz
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The EH-d30(d31) transformer station is built for voltages up to 6.6 kV and supplies power to, and controls, devices of mining machinery and equipment. It can be installed in underground workings of non-methane and methane mines. The design was developed to meet Directive 2014/34/EU (ATEX).
The electrical safety measures and the control and cooperation system with technological interlocks, which uses intrinsically safe circuits, allow safe cooperation with the power supply devices of mining machines. The station can be connected to a data transmission system, so technological information is read and passed to the mine surface, for example to the dispatcher.
The station offers many designs of main and auxiliary circuits, remote or local control and a compact construction. The number of three-phase main outlets and of three-phase and single-phase auxiliary outlets up to 230 V depends on the configuration, and the manufacturer shows an example configuration diagram.
Main data: rated power up to 2600 kVA, primary voltage up to 6600 V, secondary voltage up to 4160 V, frequency 50 or 60 Hz, connection groups Dyn5, Yyn0, Dyn5yn5 and Yyn0yn0 (other groups are possible), rated current of a single main outlet up to 630 A and weight up to 11800 kg. Appearance, dimensions and description are given in the manufacturer's documentation.
Technical specifications
| Rated power | up to 2600 kVA |
|---|---|
| Rated primary voltage | up to 6600 V |
| Rated secondary voltage | up to 4160 V |
| Rated frequency | 50, 60 Hz |
| Group of connections | Dyn5, Yyn0, Dyn5yn5, Yyn0yn0 (other groups possible) |
| Number of three-phase main outlets | depends on the configuration |
| Number of three-phase auxiliary outlets up to 230 V | depends on the configuration |
| Number of single-phase auxiliary outlets up to 230 V | depends on the configuration |
| Rated current of a single main outlet | up to 630 A |
| Device weight | up to 11800 kg |
| Directive | 2014/34/EU (ATEX) |
How it compares with similar models
| Parameter | EH-d30(d31) transformer station up to 6.6 kV for mining machinery | EH-d32 low-housing transformer station up to 6.6 kV | EH-d09 transformer assembly up to 1.1 kV for mining machinery | Smart CSS i1000 |
|---|---|---|---|---|
| Rated power | up to 2600 kVA | up to 1030 kVA | up to 10 kVA | — |
| Number of single-phase auxiliary outlets up to 230 V | depends on the configuration | depends on the configuration | up to 6 | — |
| Device weight | up to 11800 kg | up to 8050 kg | up to 450 kg | — |
Request a price and lead time
EH-d30(d31) transformer station up to 6.6 kV for mining machinery. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where can the EH-d30(d31) be installed?
In underground workings of non-methane and methane mines, to supply and control devices of mining machinery.
What are the main ratings?
Rated power up to 2600 kVA, primary voltage up to 6600 V, secondary up to 4160 V, frequency 50 or 60 Hz and up to 630 A per main outlet.
Which connection groups are available?
Dyn5, Yyn0, Dyn5yn5 and Yyn0yn0, and other connection groups are possible.
Other analogues
European analogues of КТПВ from other manufacturers and series.





Similar equipment from other manufacturers