SURGE surge suppressors for 4 to 20 mA loops and RS-422/RS-485 data lines

The SURGE family protects process instruments against lightning, power spikes and other overvoltage. It gives up to 3 kA of protection per line at subnanosecond speed. Versions are made for field-mount enclosures, DIN rail, 4 to 20 mA loops and RS-422/RS-485 lines.

Series
SURGE
Type
Surge suppressors
Protection
Up to 3 kA per line
Response speed
Subnanosecond

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SURGE family of suppressors protects a process against failures caused by lightning, power spikes and many other types of overvoltage. Overvoltage damage can gradually reduce measurement accuracy and product quality, or destroy a unit outright and force an unnecessary and costly shutdown. The suppressors give up to 3 kA of surge protection per line at subnanosecond speeds.

They protect against power fluctuations such as switching of inductive loads, arcing switch contacts, cycling motors, clearing fuses, tripping circuit breakers and power outages. A safety feature resets the suppressor automatically after each surge, and installation is easy, so the devices are maintenance-free.

Four versions exist. The 205-863-12 is a compact 28 V DC field-mount suppressor that fits into the manufacturer's field-mount enclosures to protect a 4 to 20 mA line. The 205-863-21 is a small DIN-rail unit for 4 to 20 mA loops where space is tight. The 205-863-01 is a plug-in terminal block suppressor that inserts into the terminals of DIN-style housings. The 205-863-07 is a 12 V DC rail-mount suppressor for RS-422 and RS-485 data lines.

The 205-863-12 and 205-863-21 pass HART signals, so they protect both analogue and HART lines. They exceed severity level 4 of IEC 61000-4-4, are encapsulated and suit harsh industrial environments. The field-mount version is FM and CSA approved in explosion-proof BH and SB enclosures.

The part numbers are 205-863-12, 205-863-21, 205-863-01 and 205-863-07.

Technical specifications

SeriesSURGE
TypeSurge suppressors
ProtectionUp to 3 kA per line
Response speedSubnanosecond
205-863-12Field-mount, 28 V DC, 4 to 20 mA loop
205-863-21Compact, DIN rail, 4 to 20 mA loop
205-863-01Plug-in terminal block, 4 to 20 mA loop
205-863-0712 V DC, DIN rail, RS-422 and RS-485 lines
ResetAutomatic after each surge
HART signalPasses through 205-863-12 and 205-863-21
Field-mount approvalsFM, CSA

Part numbers

Show all part numbers (4)

205-863-12, 205-863-21, 205-863-01, 205-863-07

Request a price and lead time

SURGE surge suppressors for 4 to 20 mA loops and RS-422/RS-485 data lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What protection level do the SURGE suppressors give?

Up to 3 kA per line at subnanosecond speed.

Which lines are covered?

4 to 20 mA loops (205-863-12, -21, -01) and RS-422 and RS-485 data lines (205-863-07).

Is maintenance needed after a surge?

No, the suppressor resets automatically after each surge.