International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

POWERSAFE™ medium-voltage process heating platform with integrated controls, up to 7200 V

An electric process heating package that takes medium-voltage supply straight to the heater, with the power stage, process controller and low-voltage control enclosure supplied as one system. It is aimed at plants moving large thermal duties away from fuel-fired equipment.

Type
Integrated medium-voltage electric heating platform
Product family
Circulation heaters
Operating voltage
up to 7200 V
SCR/contactor circuit power
up to 20 MW (IEC sheet: up to 15 MW)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Heaters are built from 16NPS to 36NPS and in lengths up to 20 feet, and the platform scales to heating systems beyond 100 MW. Longer bundles let a designer merge several exchangers into fewer vessels, while the flow path and film temperature control keep coil temperatures down, so a vessel can perform consistently at a shorter length.

The case for medium voltage is simple. Feeding the heater at up to 7200 V removes the step-down transformers and extra cabling that a low-voltage scheme would need, and the lower current cuts cable costs by as much as 90%. The power stage mixes SCR and contactor circuits as the duty requires: the product page quotes up to 20 MW, whereas the IEC specification sheet gives 15 MW. Power stage efficiency is above 96%, and zero-cross thyristor firing keeps electromagnetic interference low. The controller is also smaller and lighter than a conventional arrangement.

Control sits in a separate, isolated low-voltage enclosure fitted with an HMI and PLC, which handles the heater loop and talks to the plant DCS. On the protection side there is an optional feeder panel with a high-speed protective relay and breaker for rapid shutdown, plus interlocks in both the controller and the heater.

The incoming MV feed enters by bottom-entry cable or by bus bar from the feeder panel; the load side leaves through an outgoing reactor and bottom-exit cable. Versions are built to UL and to IEC requirements. For an enquiry, please give the process fluid and flow, inlet and outlet temperatures, required duty, supply voltage and any hazardous-area classification.

Technical specifications

TypeIntegrated medium-voltage electric heating platform
Product familyCirculation heaters
Operating voltageup to 7200 V
SCR/contactor circuit powerup to 20 MW (IEC sheet: up to 15 MW)
Heating system sizeover 100 MW
Power stage efficiency> 96%
Heater sizes16NPS to 36NPS
Heater lengthup to 20 feet
Controlzero-cross SCR, HMI, PLC, DCS link
MV feedbottom-entry cable or bus bar from feeder panel
MV load connectionoutgoing load reactor, bottom-exit cable
Protectionfeeder panel with relay and breaker; interlocks in controller and heater
VersionsUL; IEC

Request a price and lead time

POWERSAFE™ medium-voltage process heating platform with integrated controls, up to 7200 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What supply voltage does POWERSAFE™ accept?

It runs at medium voltage up to 7200 V, so no step-down transformer is needed.

What heater sizes are available?

From 16NPS to 36NPS in lengths up to 20 feet, and the platform supports heating systems above 100 MW.

How does it connect to the plant control system?

An isolated low-voltage enclosure houses the HMI and PLC, which control the heater and communicate with the DCS.