TG300 TRUNKGUARD fieldbus device coupler for Zone 1, TG308-DIN with 8 spurs
The TG300 TRUNKGUARD series simplifies the use of high-power and Exd fieldbus devices in Zone 1 by allowing live access for maintenance. The TG308-DIN model has 8 spurs and mounts on DIN rail.
- Series
- TG300 TRUNKGUARD Series 300
- Model
- TG308-DIN
- Type
- Fieldbus device coupler
- Protocols
- FOUNDATION fieldbus H1; PROFIBUS PA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TG300 TRUNKGUARD Series 300 device couplers connect several devices to a main trunk on FOUNDATION fieldbus H1 and PROFIBUS PA networks. They ease the use of high-power or Exd devices in Zone 1, because live access for maintenance removes the need for costly Exd/flameproof junction boxes. Models handle four or eight fieldbus devices.
A key-operated magnetic interlock lets one spur be de-energised and serviced without shutting down the whole segment, even with high-power Exd/Exn loads. Electronic, self-resetting short-circuit protection switches off any spur drawing more than 48 mA and reconnects it once the short is removed. Reconnection takes place within 20 microseconds.
Automatic segment termination removes start-up errors caused by under- or over-termination and keeps the local part of a segment working if a cable breaks downstream. The -MT option omits the auto-terminator when external termination is preferred. LEDs show spur power, spur short circuits and the state of auto termination.
Key figures are a supply voltage of 10 to 32 V DC and a maximum segment current of 800 mA. Quiescent current is 13 mA at 32 V and 5 mA at 16 V for the TG304, and 23 mA at 32 V and 10 mA at 16 V for the TG308, with 3 mA less for the -MT option. Maximum spur output current ISlim is 48 mA, spur short-circuit load ISsc is 5 mA at 32 V and 3 mA at 16 V, and spur voltage drop is 0.7 V at 20 mA. Spur wiring is limited to 120 m.
The DIN units fit 32 mm (EN50035) G-type and 35 mm (EN50022) Top Hat rail and can be mounted at any angle. Series marking: II 2 G D, EEx me II T5, with Ta from -40 °C to +70 °C. Ready-to-install glass-reinforced polyester (GRP) Exe enclosures can be ordered. Approvals are Zone 1 and Zone 2, and the unit is RoHS compliant.
Technical specifications
| Series | TG300 TRUNKGUARD Series 300 |
|---|---|
| Model | TG308-DIN |
| Type | Fieldbus device coupler |
| Protocols | FOUNDATION fieldbus H1; PROFIBUS PA |
| Power | Bus powered, 10 to 32 V DC |
| Housing | No enclosure, DIN rail only |
| Number of spurs | 8 |
| Maximum segment current | 800 mA |
| TG308 quiescent current | 23 mA at 32 V; 10 mA at 16 V |
| Maximum spur output current | ISlim = 48 mA |
| Spur voltage drop | 0.7 V at 20 mA |
| Spur wiring length | Up to 120 m |
| Approvals | Zone 1, Zone 2 |
| Series marking | II 2 G D, EEx me II T5 |
| Temperature range | -40 °C to +70 °C |
| RoHS compliant | Yes |
Part numbers
Show all part numbers (1)
TG308-DIN
How it compares with similar models
| Parameter | TG300 TRUNKGUARD fieldbus device coupler for Zone 1, TG308-DIN with 8 spurs | TS200 TRUNKSAFE fault-tolerant fieldbus device coupler, 12 spurs | TG208-DIN 8-Spur Fieldbus Device Coupler for FOUNDATION fieldbus H1 and PROFIBUS PA | RMA100C intrinsically-safe fieldbus device couplers, FISCO or ENTITY, ROUTE-MASTER series |
|---|---|---|---|---|
| Type | Fieldbus device coupler | Fault-tolerant fieldbus device coupler | Fieldbus device coupler, 8 spurs, no enclosure | Intrinsically-safe fieldbus device coupler |
| Power | Bus powered, 10 to 32 V DC | Bus powered | Bus powered, 10-32 Vdc | Bus powered |
| Number of spurs | 8 | 12 | — | 4 |
| Approvals | Zone 1, Zone 2 | Non-Incendive/Div. 2, Zone 2, General Purpose | — | Intrinsically-Safe, Non-Incendive/Div. 2, Zone 2, General Purpose |
Request a price and lead time
TG300 TRUNKGUARD fieldbus device coupler for Zone 1, TG308-DIN with 8 spurs. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the TG300 offer in Zone 1?
Live access to spurs for maintenance, and no need for costly Exd/flameproof junction boxes.
How are spurs protected against short circuits?
A spur drawing more than 48 mA is switched off automatically and reconnects when the short is removed.
What are the supply and segment current limits?
Supply of 10 to 32 V DC and a maximum segment current of 800 mA.