ENVIROSEAL™ HD sealed resistance temperature sensor for wet, oily and high-vibration duty, -40 to 200 °C
A heavy-duty resistance temperature sensor sealed against water, oil and dirt, intended for machinery that runs outdoors or shakes hard. It covers -40 to 200 °C and keeps the accuracy of the RTD or thermistor element fitted inside.
- Type
- resistance temperature sensor
- Sensing element
- RTD or thermistor
- Range, °C
- -40 to 200 °C
- Range, °F
- -40 to 392 °F
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Water ingress and vibration are the two usual reasons a temperature probe fails early on heavy-duty plant that stands outdoors or sits in oil. ENVIROSEAL™ HD is built around both problems: the measuring section is sealed so that moisture, oil and other contaminants cannot reach the element, and the assembly is designed to give steady readings on equipment that vibrates heavily.
The manufacturer lists the series among its resistance temperature sensors, so the element inside is either a resistance thermometer (RTD) or a thermistor. Accuracy is therefore the same as for that element in the chosen tolerance class; the sealing adds no penalty to the reading.
The working span runs from -40 to 200 °C, which is -40 to 392 °F. That covers most low and medium temperature measurements on equipment working in oil, spray and damp air. For hotter duties the same catalogue offers thermocouple assemblies.
When enquiring, state the element type, the tolerance class and how the sensor will be connected to the instrument. Any controller or transmitter with an RTD or thermistor input can read the signal. Outdoor installations exposed to rain, spray and oil mist are the natural home for this sensor, particularly where standard probes have needed frequent replacement.
Technical specifications
| Type | resistance temperature sensor |
|---|---|
| Sensing element | RTD or thermistor |
| Range, °C | -40 to 200 °C |
| Range, °F | -40 to 392 °F |
| Accuracy | as for the fitted RTD or thermistor |
| Protection | sealed against moisture, oil and contaminants |
| Service conditions | high vibration, outdoor installation |
Request a price and lead time
ENVIROSEAL™ HD sealed resistance temperature sensor for wet, oily and high-vibration duty, -40 to 200 °C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What temperature range does ENVIROSEAL™ HD cover?
It operates from -40 to 200 °C, equivalent to -40 to 392 °F.
How accurate is the sensor?
Accuracy follows the tolerance of the element fitted, namely a standard RTD or thermistor of the selected class.
Can it be installed outdoors?
Yes, the series is intended for outdoor equipment exposed to rain, oil and heavy moisture, and for locations with strong vibration.