International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3

The TIGRON in SIL version is an explosion-proof actuator for the highest safety requirements, up to SIL 3. Torque is 10 Nm to 1000 Nm, output speed 4 1/min to 216 1/min, enclosure IP68. It is certified by TÜV Nord to IEC 61508 and ISO 13849.

Type
Explosion-proof actuator with SIL safety functions
Safety level
up to SIL 3; SIL 2 at HFT=0 and SC=3, SIL 3 with redundancy
Certification
TÜV Nord, IEC 61508 (SIL), ISO 13849 (PL)
Safety functions
up to 4 per device: Safe OPENING/Safe CLOSING (ESD), with timer, Safe STOP, safe end position feedback

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

This is the safety-rated version of the TIGRON multi-turn actuator. It meets safety requirements up to SIL 3 and is explosion-proof. Up to four different safety functions can be configured for each device, and their priority is freely defined.

The safety functions are Safe OPENING/Safe CLOSING (ESD), the same with a timer function to avoid pressure surges, Safe STOP and safe end position feedback. They are SIL 2 capable for HFT=0 and SC=3, and SIL 3 capable when used with redundancy. There are five SIL assessed outputs. TÜV Nord certifies the actuator in compliance with IEC 61508 (SIL) and ISO 13849 (PL), and safety-related software controls and monitors the functions.

The type of seating in the end position can be set separately for Safe OPENING, Safe CLOSING and standard functions: forced limit seating, forced torque seating or no seating. Overload protection and a torque bypass can be configured for safety operations.

Torque is 10 Nm to 1000 Nm, output speeds are 4 1/min to 216 1/min and the modulating torque range is 10 Nm to 1000 Nm. The enclosure is IP68, corrosion protection is C5/CX, and the ambient temperature range is -63 °C to +70 °C. The ATEX marking is Ex db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db. Position sensing reaches 5000 turns per stroke, and Profibus and Modbus interfaces are available.

Technical specifications

TypeExplosion-proof actuator with SIL safety functions
Safety levelup to SIL 3; SIL 2 at HFT=0 and SC=3, SIL 3 with redundancy
CertificationTÜV Nord, IEC 61508 (SIL), ISO 13849 (PL)
Safety functionsup to 4 per device: Safe OPENING/Safe CLOSING (ESD), with timer, Safe STOP, safe end position feedback
SIL assessed outputs5
Torque range10 Nm - 1000 Nm
Output speeds4 1/min - 216 1/min
Modulating torque range10 Nm - 1000 Nm
Enclosure protectionIP68
Corrosion protectionC5/CX
Ambient temperature-63 °C - +70 °C
ATEX markingEx db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db

How it compares with similar models

ParameterTIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3TIGRON-M explosion-proof multi-turn actuators, 10–1000 NmSQREx .2 explosion-proof part-turn actuators for modulating duty, 50–2400 NmSQRVEx .2 explosion-proof variable-speed actuators for modulating duty
TypeExplosion-proof actuator with SIL safety functionsExplosion-proof multi-turn actuatorExplosion-proof part-turn actuator for modulating dutyExplosion-proof variable-speed actuator for modulating duty
Torque range10 Nm - 1000 Nm10 Nm - 1000 Nm50 Nm - 2400 Nm150 Nm - 2400 Nm
Modulating torque range10 Nm - 1000 Nm10 Nm - 1000 Nm75 Nm - 1200 Nm75 Nm - 1200 Nm
Corrosion protectionC5/CXC5/CXKSKS
Ambient temperature-63 °C - +70 °C-65 °C - +75 °C-30 °C - +40/+60 °C-30 °C - +40/+60 °C
ATEX markingEx db eb h IIC T4 Gb, Ex h tb IIIC T130 °C DbEx db eb h IIC T4 Gb, Ex h tb IIIC T130 °C DbII 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3)II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3)

Request a price and lead time

TIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which SIL level does the TR-M SIL reach?

The safety functions are SIL 2 capable for HFT=0 and SC=3, and SIL 3 capable with redundancy.

How many safety functions can be configured?

Up to four per device, with a freely defined priority.

Who certifies the actuator?

TÜV Nord, in compliance with IEC 61508 (SIL) and ISO 13849 (PL).