TIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3
The TIGRON in SIL version is an explosion-proof actuator for the highest safety requirements, up to SIL 3. Torque is 10 Nm to 1000 Nm, output speed 4 1/min to 216 1/min, enclosure IP68. It is certified by TÜV Nord to IEC 61508 and ISO 13849.
- Type
- Explosion-proof actuator with SIL safety functions
- Safety level
- up to SIL 3; SIL 2 at HFT=0 and SC=3, SIL 3 with redundancy
- Certification
- TÜV Nord, IEC 61508 (SIL), ISO 13849 (PL)
- Safety functions
- up to 4 per device: Safe OPENING/Safe CLOSING (ESD), with timer, Safe STOP, safe end position feedback
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
This is the safety-rated version of the TIGRON multi-turn actuator. It meets safety requirements up to SIL 3 and is explosion-proof. Up to four different safety functions can be configured for each device, and their priority is freely defined.
The safety functions are Safe OPENING/Safe CLOSING (ESD), the same with a timer function to avoid pressure surges, Safe STOP and safe end position feedback. They are SIL 2 capable for HFT=0 and SC=3, and SIL 3 capable when used with redundancy. There are five SIL assessed outputs. TÜV Nord certifies the actuator in compliance with IEC 61508 (SIL) and ISO 13849 (PL), and safety-related software controls and monitors the functions.
The type of seating in the end position can be set separately for Safe OPENING, Safe CLOSING and standard functions: forced limit seating, forced torque seating or no seating. Overload protection and a torque bypass can be configured for safety operations.
Torque is 10 Nm to 1000 Nm, output speeds are 4 1/min to 216 1/min and the modulating torque range is 10 Nm to 1000 Nm. The enclosure is IP68, corrosion protection is C5/CX, and the ambient temperature range is -63 °C to +70 °C. The ATEX marking is Ex db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db. Position sensing reaches 5000 turns per stroke, and Profibus and Modbus interfaces are available.
Technical specifications
| Type | Explosion-proof actuator with SIL safety functions |
|---|---|
| Safety level | up to SIL 3; SIL 2 at HFT=0 and SC=3, SIL 3 with redundancy |
| Certification | TÜV Nord, IEC 61508 (SIL), ISO 13849 (PL) |
| Safety functions | up to 4 per device: Safe OPENING/Safe CLOSING (ESD), with timer, Safe STOP, safe end position feedback |
| SIL assessed outputs | 5 |
| Torque range | 10 Nm - 1000 Nm |
| Output speeds | 4 1/min - 216 1/min |
| Modulating torque range | 10 Nm - 1000 Nm |
| Enclosure protection | IP68 |
| Corrosion protection | C5/CX |
| Ambient temperature | -63 °C - +70 °C |
| ATEX marking | Ex db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db |
How it compares with similar models
| Parameter | TIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3 | TIGRON-M explosion-proof multi-turn actuators, 10–1000 Nm | SQREx .2 explosion-proof part-turn actuators for modulating duty, 50–2400 Nm | SQRVEx .2 explosion-proof variable-speed actuators for modulating duty |
|---|---|---|---|---|
| Type | Explosion-proof actuator with SIL safety functions | Explosion-proof multi-turn actuator | Explosion-proof part-turn actuator for modulating duty | Explosion-proof variable-speed actuator for modulating duty |
| Torque range | 10 Nm - 1000 Nm | 10 Nm - 1000 Nm | 50 Nm - 2400 Nm | 150 Nm - 2400 Nm |
| Modulating torque range | 10 Nm - 1000 Nm | 10 Nm - 1000 Nm | 75 Nm - 1200 Nm | 75 Nm - 1200 Nm |
| Corrosion protection | C5/CX | C5/CX | KS | KS |
| Ambient temperature | -63 °C - +70 °C | -65 °C - +75 °C | -30 °C - +40/+60 °C | -30 °C - +40/+60 °C |
| ATEX marking | Ex db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db | Ex db eb h IIC T4 Gb, Ex h tb IIIC T130 °C Db | II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3) | II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3) |
Request a price and lead time
TIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which SIL level does the TR-M SIL reach?
The safety functions are SIL 2 capable for HFT=0 and SC=3, and SIL 3 capable with redundancy.
How many safety functions can be configured?
Up to four per device, with a freely defined priority.
Who certifies the actuator?
TÜV Nord, in compliance with IEC 61508 (SIL) and ISO 13849 (PL).
Similar equipment from other manufacturers