TIGRON Fail Safe electric actuator with mechanical fail safe, 2000–60000 Nm

TIGRON Fail Safe combines high torque and short closing times with a purely mechanical fail safe function. Torque is 2000 Nm to 60000 Nm, a 90° stroke takes 1 s to 60 s, enclosure IP 68. Critical valves open or close safely without mains supply.

Type
Electric actuator with mechanical fail safe
Torque range
2000 Nm - 60000 Nm
Operating time for 90°
1 s - 60 s
Swing angle
90 °

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TIGRON Fail Safe is an electric actuator for critical valves that must reach a safe position in an emergency. Its fail safe function is purely mechanical, so opening or closing takes place even when there is no mains supply.

A mechanical return spring supplies the energy after a power failure, and a scotch yoke mechanism transmits that energy to the valve. Pneumatic or hydraulic systems, which are prone to errors, are not required, and this reduces costs.

The actuator delivers 2000 Nm to 60000 Nm and swings the valve through 90 ° in 1 s to 60 s. The enclosure is IP 68 and the ambient temperature range is - 65 °C to +75 °C.

The actuator combines an intelligent electric drive with rugged, high-precision mechanics. The mechanical side is the return spring and the scotch yoke mechanism; the electric side is the control that communicates with the DCS. No auxiliary pneumatic or hydraulic circuits are needed, and the fail safe movement itself does not rely on electronics or on the network.

All components need little maintenance and show low wear. Communication with the DCS includes feedback on the valve position, and diagnostic functions help keep the actuator available.

Technical specifications

TypeElectric actuator with mechanical fail safe
Torque range2000 Nm - 60000 Nm
Operating time for 90°1 s - 60 s
Swing angle90 °
Enclosure protectionIP 68
Ambient temperature- 65 °C - +75 °C
Energy source on power failuremechanical return spring
Transmission to valvescotch yoke

How it compares with similar models

ParameterTIGRON Fail Safe electric actuator with mechanical fail safe, 2000–60000 NmTIGRON-M explosion-proof multi-turn actuators, 10–1000 NmTIGRON TR-M SIL explosion-proof actuator for safety applications up to SIL 3SQ .2 part-turn actuators for open-close duty, 50–2500 Nm
TypeElectric actuator with mechanical fail safeExplosion-proof multi-turn actuatorExplosion-proof actuator with SIL safety functionsPart-turn actuator
Torque range2000 Nm - 60000 Nm10 Nm - 1000 Nm10 Nm - 1000 Nm50 Nm - 2500 Nm
Enclosure protectionIP 68IP68IP68IP68
Ambient temperature- 65 °C - +75 °C-65 °C - +75 °C-63 °C - +70 °C-30 °C - +70 °C

Request a price and lead time

TIGRON Fail Safe electric actuator with mechanical fail safe, 2000–60000 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What happens on loss of power?

A mechanical return spring supplies the energy and a scotch yoke mechanism passes it to the valve.

Is pneumatics or hydraulics needed?

No. Pneumatic or hydraulic systems are not required.

What torque and operating time are covered?

2000 Nm to 60000 Nm, with 1 s to 60 s for 90°.