AC 01.2-SIL / ACExC 01.2-SIL Actuator Controls with SIL Module, up to SIL 3
AC 01.2-SIL and ACExC 01.2-SIL carry an additional SIL module that executes safety functions. SA .2 and SQ .2 actuators combined with them can be used in safety-related systems up to SIL 3. TÜV certified to IEC 61508 Ed. 2, enclosure IP 68.
- Type
- Actuator controls with SIL module
- Series
- AC 01.2-SIL / ACExC 01.2-SIL
- Enclosure protection
- IP 68
- Corrosion protection
- KS
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
For premium safety requirements the range offers AC 01.2-SIL and ACExC 01.2-SIL actuator controls. Combined with them, SA .2 and SQ .2 actuators can be deployed in safety-related systems up to SIL 3. In the SIL version an AC 01.2 receives an extra module designed to execute safety functions. If an emergency occurs at the plant and a safety function is requested, the standard logic is bypassed and the safe SIL module performs the function, so the safety function always overrules normal operation.
SA .2 and SQ .2 actuators equipped with these controls are certified by TÜV Nord for the following safety functions: safe OPENING/CLOSING (ESD) up to SIL 2 in a single-channel system or SIL 3 in a redundant system, according to IEC 61508 Ed. 2; safe STOP up to SIL 2 in a single-channel system; and a safe end position feedback signal up to SIL 2 according to IEC 61508 Ed. 2 or up to PL c according to ISO 13849. The feedback signal is not part of the certificate; a separate declaration of incorporation is available. Redundant setups such as 1oo2 reach SIL 3.
The available functions are safe OPENING (ESD), safe CLOSING (ESD), safe STOP OPEN and safe STOP CLOSE, and combinations of safe STOP OPEN/CLOSE with either ESD function. For safety operation you can select forced limit seating in the end position, forced limit seating with overload protection, forced torque seating, or no seating. Safety functions are triggered through wire break-proof (low active) 24 V DC inputs, with a redundant setup for the ESD function.
Otherwise the controls share the AC 01.2 feature set: local controls with lockable selector switch, push buttons and indication lights, LCD, motor control by reversing contactors or thyristors, PID process controller and analogue control 0/4 – 20 mA. Fieldbus options are Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus and Wireless HART, and a Bluetooth interface serves notebooks and Android tablets.
Service conditions are IP 68, corrosion protection KS and ambient temperature -25 °C – +40/+60 °C. The ACExC version is explosion-protected: ATEX Ex de IIC/IIB T4 (T3) and Ex d IIC/IIB T4 (T3), IECEx Ex de IIC/IIB T4 (T3) and Ex d IIC/IIB T4 (T3), FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and FM CLASS III DIV 1 T4 (T3). The electrical connection is a plug/socket connector made by the manufacturer, with terminals as an alternative.
Technical specifications
| Type | Actuator controls with SIL module |
|---|---|
| Series | AC 01.2-SIL / ACExC 01.2-SIL |
| Enclosure protection | IP 68 |
| Corrosion protection | KS |
| Ambient temperature | -25 °C – +40/+60 °C |
| Safe OPENING/CLOSING (ESD) | Up to SIL 2 (single-channel), up to SIL 3 (redundant) |
| Safe STOP | Up to SIL 2 (single-channel) |
| Safe end position feedback | Up to SIL 2 per IEC 61508 Ed. 2 or up to PL c per ISO 13849 |
| ATEX explosion protection | Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3) |
| FM explosion protection | FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C); FM CLASS III DIV 1 T4 (T3) |
| IECEx (International/Australia) | Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3) |
| Safety function inputs | 24 V DC, wire break-proof, redundant setup for ESD |
| Fieldbus | Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus, Wireless HART |
How it compares with similar models
| Parameter | AC 01.2-SIL / ACExC 01.2-SIL Actuator Controls with SIL Module, up to SIL 3 | ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus | AMExC 01.1 Explosion-Proof Simple Actuator Controls, IP 68, -40 °C – +40/+60 °C | AM Simple Actuator Controls with Parallel Signal Transmission, IP 68, -30 °C – +70 °C |
|---|---|---|---|---|
| Type | Actuator controls with SIL module | Explosion-proof microprocessor-based actuator controls | Explosion-proof simple actuator controls | Simple actuator controls with basic functions |
| Enclosure protection | IP 68 | IP68 | IP 68 | IP 68 |
| Ambient temperature | -25 °C – +40/+60 °C | -30 °C – +40/+60 °C | -40 °C – +40/+60 °C | -30 °C – +70 °C |
Request a price and lead time
AC 01.2-SIL / ACExC 01.2-SIL Actuator Controls with SIL Module, up to SIL 3. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Up to which SIL level are these controls suitable?
Safe OPENING/CLOSING (ESD) reaches SIL 2 in a single-channel system and SIL 3 in a redundant one; safe STOP reaches SIL 2 in a single-channel system.
What happens to the standard logic when a safety function is requested?
The standard logic is bypassed and the SIL module executes the function, so the safety function always overrules normal operation.
Which seating types can be selected for safety operation?
Forced limit seating in the end position, forced limit seating with overload protection, forced torque seating, or no seating.