AM Simple Actuator Controls with Parallel Signal Transmission, IP 68, -30 °C – +70 °C
AM actuator controls are a plain design with basic functions for parallel signal transmission. Operation commands OPEN, STOP, CLOSE; end position and collective fault feedback; valve position as an optional 0/4 – 20 mA signal. Enclosure IP 68, corrosion protection KS.
- Type
- Simple actuator controls with basic functions
- Series
- AM
- Enclosure protection
- IP 68
- Corrosion protection
- KS
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
AM actuator controls have a straightforward design and basic functions, and suit installations that use parallel signal transmission with a relatively low number of feedback signals. A few parameters are defined on sliding switches during commissioning, for example the type of seating in the end positions.
Control is by the operation commands OPEN, STOP and CLOSE. Reaching an end position and collective fault signals are reported back to the DCS as feedback signals, and the same signals are shown by the indication lights of the local controls. As an option the valve position can be sent to the DCS as a 0/4 – 20 mA signal.
Design features include a modular interface concept for remote control, local controls with a lockable selector switch, push buttons and indication lights, programmable control logic (push-to-run operation or self-retaining), programmable type of seating (limit or torque seating), optional separate mounting on a wall bracket, and phase monitoring with automatic phase correction. The motor is switched by reversing contactors or thyristors (option), and an external 24 VDC supply can be added.
On the interface side there are control inputs for different voltages (DC/AC), potential-free output contacts for status signalling and a fieldbus interface. Selected configurations allow safe end position feedback up to SIL 2.
The enclosure is rated IP 68 with corrosion protection KS, for ambient temperatures from -30 °C to +70 °C. The electrical connection is a manufacturer plug/socket connector with terminals as an option, and cable entries come in different versions.
Technical specifications
| Type | Simple actuator controls with basic functions |
|---|---|
| Series | AM |
| Enclosure protection | IP 68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C – +70 °C |
| Operation commands | OPEN, STOP, CLOSE |
| Valve position (option) | 0/4 – 20 mA |
| Control logic | Push-to-run operation or self-retaining (programmable) |
| Type of seating | Limit or torque seating (programmable) |
| Motor control | Reversing contactors or thyristors (option) |
| External supply (option) | 24 VDC |
| Functional safety | Safe end position feedback up to SIL 2 (selected configurations) |
How it compares with similar models
| Parameter | AM Simple Actuator Controls with Parallel Signal Transmission, IP 68, -30 °C – +70 °C | AMExC 01.1 Explosion-Proof Simple Actuator Controls, IP 68, -40 °C – +40/+60 °C | AC / ACV (AC 01.2) Microprocessor-Based Actuator Controls with Fieldbus, IP68 | ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus |
|---|---|---|---|---|
| Type | Simple actuator controls with basic functions | Explosion-proof simple actuator controls | Microprocessor-based actuator controls | Explosion-proof microprocessor-based actuator controls |
| Enclosure protection | IP 68 | IP 68 | IP68 | IP68 |
| Ambient temperature | -30 °C – +70 °C | -40 °C – +40/+60 °C | -30 °C – +70 °C | -30 °C – +40/+60 °C |
| Motor control | Reversing contactors or thyristors (option) | Reversing contactors or thyristors (option) | Reversing contactors, thyristors | Reversing contactors, thyristors |
| External supply (option) | 24 VDC | 24 VDC | 24 V DC | 24 V DC |
Request a price and lead time
AM Simple Actuator Controls with Parallel Signal Transmission, IP 68, -30 °C – +70 °C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which signals does the AM report back to the DCS?
Reaching an end position and a collective fault signal, plus the valve position as an optional 0/4 – 20 mA signal.
What is set during commissioning?
A few parameters on sliding switches, for example the type of seating in the end positions.
Which control logic can be programmed?
Push-to-run operation or self-retaining, together with limit or torque seating.
Similar equipment from other manufacturers