International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus

ACExC 01.2 are explosion-proof, microprocessor-based actuator controls with integral local controls, offered for SAEx/SAREx 07.2 – 16.2 multi-turn and SQEx/SQREx 05.2 – 14.2 part-turn actuators. ATEX, IECEx and FM approvals, enclosure IP68, fieldbus interfaces including Profibus, Profinet, Modbus and HART.

Type
Explosion-proof microprocessor-based actuator controls
Series
ACExC 01.2
Enclosure protection
IP68
Corrosion protection
KS

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Explosion-proof devices must be used in plants where potentially explosive atmospheres are likely to occur. They are designed not to act as an ignition source, producing neither ignition sparks nor hot surface temperatures, and certification is carried out in close collaboration with national and international certification bodies. ACExC 01.2 actuator controls with integral local controls are available for SAEx/SAREx 07.2 – SAEx/SAREx 16.2 multi-turn actuators and SQEx/SQREx 05.2 – SQEx/SQREx 14.2 part-turn actuators.

The ACExC is a microprocessor-based unit with a full function set. Its interface concept is modular for remote control. Local controls comprise a lockable selector switch, push buttons and indication lights, and an LCD supports status monitoring and parametrisation. Actuator setting and parametrisation are non-intrusive when the MWG magnetic limit and torque transmitter is fitted. The controls may be wall-mounted separately. Reversing contactors or thyristors switch the motor, phase monitoring corrects the phase sequence automatically, and an external 24 V DC supply is optional.

On the interface side there are control inputs for different voltages (DC/AC), programmable potential-free output contacts, analogue control 0/4 – 20 mA, a programmable stepping mode to extend running time, freely definable intermediate positions and a PID process controller. Behaviour in emergencies and on communication loss can be programmed, and limit and torque signals can be output in analogue form with the MWG. Fieldbus options are Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, Foundation Fieldbus, HART and Wireless HART, with component redundancy available for the bus interface. Operation data is logged, and a Bluetooth link connects a notebook or Android tablet.

Explosion protection is ATEX Ex de IIC/IIB T4 (T3) and Ex d IIC/IIB T4 (T3), IECEx Ex de IIC/IIB T4 (T3) and Ex d IIC/IIB T4 (T3), plus FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and FM CLASS III DIV 1 T4 (T3). The enclosure is IP68, corrosion protection KS, ambient temperature -30 °C – +40/+60 °C. The electrical connection is a manufacturer plug/socket connector with terminals as an alternative; cable entries come in several versions and fieldbus interfaces have an FOC connection. Selected configurations offer safe end position feedback up to SIL 2.

Technical specifications

TypeExplosion-proof microprocessor-based actuator controls
SeriesACExC 01.2
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C – +40/+60 °C
ATEX explosion protectionEx de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3)
FM explosion protectionFM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C); FM CLASS III DIV 1 T4 (T3)
IECEx (International/Australia)Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3)
External supply (option)24 V DC
Analogue control0/4 – 20 mA
FieldbusProfibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, Foundation Fieldbus, HART, Wireless HART
Motor controlReversing contactors, thyristors
Functional safetySafe end position feedback up to SIL 2 (selected configurations)

How it compares with similar models

ParameterACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, FieldbusAC / ACV (AC 01.2) Microprocessor-Based Actuator Controls with Fieldbus, IP68AMExC 01.1 Explosion-Proof Simple Actuator Controls, IP 68, -40 °C – +40/+60 °CAC 01.2-SIL / ACExC 01.2-SIL Actuator Controls with SIL Module, up to SIL 3
TypeExplosion-proof microprocessor-based actuator controlsMicroprocessor-based actuator controlsExplosion-proof simple actuator controlsActuator controls with SIL module
Enclosure protectionIP68IP68IP 68IP 68
Ambient temperature-30 °C – +40/+60 °C-30 °C – +70 °C-40 °C – +40/+60 °C-25 °C – +40/+60 °C
External supply (option)24 V DC24 V DC24 VDC—
FieldbusProfibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, Foundation Fieldbus, HART, Wireless HARTProfibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus, WirelessHART—Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus, Wireless HART
Motor controlReversing contactors, thyristorsReversing contactors, thyristorsReversing contactors or thyristors (option)—

Request a price and lead time

ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which actuators is ACExC 01.2 intended for?

SAEx/SAREx 07.2 – SAEx/SAREx 16.2 multi-turn actuators and SQEx/SQREx 05.2 – SQEx/SQREx 14.2 part-turn actuators, with integral local controls.

What explosion protection markings does it carry?

ATEX and IECEx Ex de IIC/IIB T4 (T3) and Ex d IIC/IIB T4 (T3), plus FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and CLASS III DIV 1 T4 (T3).

What are the ambient temperature range and enclosure rating?

Ambient temperature -30 °C – +40/+60 °C, enclosure IP68 and corrosion protection KS.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides