FQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 Nm

The SIL version of the FQM fail safe unit opens or closes valves in emergencies during power failure and suits safety-related applications up to SIL 3. Torque range 150 Nm – 1200 Nm, operating time for 90° of 8 s – 54 s, enclosure IP68.

Type
Fail safe unit, SIL version, for open-close duty
Series
FQM / FQMEx SIL
Torque range
150 Nm – 1200 Nm
Operating time for 90°
8 s – 54 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

In its SIL version the FQM fail safe unit opens or closes valves in an emergency when the power fails, and it is suitable for safety-related applications up to SIL 3. The torque range is 150 Nm – 1200 Nm for open-close duty.

The torque needed in an emergency comes from energy stored mechanically in a constant force spring. Compared with conventional solutions the constant force spring motor gives constant torque characteristics across the overall torque range, and because the spring is not operated during standard operation, actuator sizing can stay relatively small.

Functional safety is certified in compliance with IEC 61508 (SIL) and EN ISO 13849 (PL). The safety functions under IEC 61508 are safe OPENING/CLOSING (ESD) and safe end position feedback. They are capable of SIL 2 for HFT=0 (hardware fault tolerance) and SC=3, and therefore of SIL 3. Under EN ISO 13849, safe end position feedback reaches PL c.

Technical data: operating time for 90° from 8 s to 54 s, swing angles from 80 ° to 100 °, enclosure IP68, corrosion protection KS, ambient temperature from -30 °C to +70 °C. Valve attachments follow the ISO standard. The electrical connection is a manufacturer plug/socket connector with cable entries in different versions.

Options are explosion protection and fire protection. Explosion protection markings: ATEX II2G Ex db eb IIB T4 Gb; FM Class I, Div. 1, Groups C, D T4 and Class I, Zone 1, Group IIB T4; IECEx Ex db eb IIB T4 Gb.

Technical specifications

TypeFail safe unit, SIL version, for open-close duty
SeriesFQM / FQMEx SIL
Torque range150 Nm – 1200 Nm
Operating time for 90°8 s – 54 s
Swing angles80 ° – 100 °
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C – +70 °C
SIL capabilityUp to SIL 2 for HFT=0 and SC=3, thus up to SIL 3
Safety functions, IEC 61508Safe OPENING/CLOSING (ESD), safe end position feedback
Safe end position feedback, EN ISO 13849Up to PL c
ATEX explosion protectionII2G Ex db eb IIB T4 Gb
FM explosion protectionClass I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4
IECEx (International/Australia)Ex db eb IIB T4 Gb

How it compares with similar models

ParameterFQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 NmFQM / FQMEx Fail Safe Unit for Open-Close Duty, 150 – 1200 NmGS Part-Turn Gearboxes, 250 – 675000 Nm, Swing Angle up to 190 °, IP68ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus
TypeFail safe unit, SIL version, for open-close dutyFail safe unit for open-close dutyPart-turn gearboxExplosion-proof microprocessor-based actuator controls
Torque range150 Nm – 1200 Nm150 Nm – 1200 Nm250 Nm – 675000 Nm—
Ambient temperature-30 °C – +70 °C-30 °C – +70 °C-60 °C – +120 °C-30 °C – +40/+60 °C
ATEX explosion protectionII2G Ex db eb IIB T4 GbII2G Ex db eb IIB T4 GbII 2G Ex h IIC T4 Gb II 2D Ex h IIIC T130 °C DbEx de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3)
FM explosion protectionClass I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4Class I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4—FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C); FM CLASS III DIV 1 T4 (T3)
IECEx (International/Australia)Ex db eb IIB T4 GbEx db eb IIB T4 Gb—Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3)

Request a price and lead time

FQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Up to which SIL level is the SIL version suitable?

Up to SIL 3: the safety functions are capable of SIL 2 for HFT=0 and SC=3, and therefore of SIL 3.

How is the emergency torque produced?

By energy stored mechanically in a constant force spring; the spring is not operated during standard operation.

Which functions are certified under IEC 61508?

Safe OPENING/CLOSING (ESD) and safe end position feedback; under EN ISO 13849 end position feedback reaches PL c.

Similar equipment from other manufacturers