FQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 Nm
The SIL version of the FQM fail safe unit opens or closes valves in emergencies during power failure and suits safety-related applications up to SIL 3. Torque range 150 Nm – 1200 Nm, operating time for 90° of 8 s – 54 s, enclosure IP68.
- Type
- Fail safe unit, SIL version, for open-close duty
- Series
- FQM / FQMEx SIL
- Torque range
- 150 Nm – 1200 Nm
- Operating time for 90°
- 8 s – 54 s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
In its SIL version the FQM fail safe unit opens or closes valves in an emergency when the power fails, and it is suitable for safety-related applications up to SIL 3. The torque range is 150 Nm – 1200 Nm for open-close duty.
The torque needed in an emergency comes from energy stored mechanically in a constant force spring. Compared with conventional solutions the constant force spring motor gives constant torque characteristics across the overall torque range, and because the spring is not operated during standard operation, actuator sizing can stay relatively small.
Functional safety is certified in compliance with IEC 61508 (SIL) and EN ISO 13849 (PL). The safety functions under IEC 61508 are safe OPENING/CLOSING (ESD) and safe end position feedback. They are capable of SIL 2 for HFT=0 (hardware fault tolerance) and SC=3, and therefore of SIL 3. Under EN ISO 13849, safe end position feedback reaches PL c.
Technical data: operating time for 90° from 8 s to 54 s, swing angles from 80 ° to 100 °, enclosure IP68, corrosion protection KS, ambient temperature from -30 °C to +70 °C. Valve attachments follow the ISO standard. The electrical connection is a manufacturer plug/socket connector with cable entries in different versions.
Options are explosion protection and fire protection. Explosion protection markings: ATEX II2G Ex db eb IIB T4 Gb; FM Class I, Div. 1, Groups C, D T4 and Class I, Zone 1, Group IIB T4; IECEx Ex db eb IIB T4 Gb.
Technical specifications
| Type | Fail safe unit, SIL version, for open-close duty |
|---|---|
| Series | FQM / FQMEx SIL |
| Torque range | 150 Nm – 1200 Nm |
| Operating time for 90° | 8 s – 54 s |
| Swing angles | 80 ° – 100 ° |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C – +70 °C |
| SIL capability | Up to SIL 2 for HFT=0 and SC=3, thus up to SIL 3 |
| Safety functions, IEC 61508 | Safe OPENING/CLOSING (ESD), safe end position feedback |
| Safe end position feedback, EN ISO 13849 | Up to PL c |
| ATEX explosion protection | II2G Ex db eb IIB T4 Gb |
| FM explosion protection | Class I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4 |
| IECEx (International/Australia) | Ex db eb IIB T4 Gb |
How it compares with similar models
| Parameter | FQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 Nm | FQM / FQMEx Fail Safe Unit for Open-Close Duty, 150 – 1200 Nm | GS Part-Turn Gearboxes, 250 – 675000 Nm, Swing Angle up to 190 °, IP68 | ACExC 01.2 Explosion-Proof Microprocessor-Based Actuator Controls, IP68, Fieldbus |
|---|---|---|---|---|
| Type | Fail safe unit, SIL version, for open-close duty | Fail safe unit for open-close duty | Part-turn gearbox | Explosion-proof microprocessor-based actuator controls |
| Torque range | 150 Nm – 1200 Nm | 150 Nm – 1200 Nm | 250 Nm – 675000 Nm | — |
| Ambient temperature | -30 °C – +70 °C | -30 °C – +70 °C | -60 °C – +120 °C | -30 °C – +40/+60 °C |
| ATEX explosion protection | II2G Ex db eb IIB T4 Gb | II2G Ex db eb IIB T4 Gb | II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T130 °C Db | Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3) |
| FM explosion protection | Class I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4 | Class I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4 | — | FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C); FM CLASS III DIV 1 T4 (T3) |
| IECEx (International/Australia) | Ex db eb IIB T4 Gb | Ex db eb IIB T4 Gb | — | Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3) |
Request a price and lead time
FQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Up to which SIL level is the SIL version suitable?
Up to SIL 3: the safety functions are capable of SIL 2 for HFT=0 and SC=3, and therefore of SIL 3.
How is the emergency torque produced?
By energy stored mechanically in a constant force spring; the spring is not operated during standard operation.
Which functions are certified under IEC 61508?
Safe OPENING/CLOSING (ESD) and safe end position feedback; under EN ISO 13849 end position feedback reaches PL c.