International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

FQM / FQMEx Fail Safe Unit for Open-Close Duty, 150 – 1200 Nm

The FQM / FQMEx fail safe unit operates valves automatically in emergencies using stored mechanical energy. It is built for open-close duty with a torque range of 150 Nm – 1200 Nm, 8 s – 54 s operating time for 90°, swing angles of 80 ° – 100 ° and IP68 protection.

Type
Fail safe unit for open-close duty
Series
FQM / FQMEx
Torque range
150 Nm – 1200 Nm
Operating time for 90°
8 s – 54 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The FQM fail safe unit provides automatic operation of valves in case of emergencies, using stored mechanical energy. It is designed for open-close duty over a torque range of 150 Nm – 1200 Nm, and the FQMEx is the explosion-protected version.

The spring is not operated during standard operation, so actuator sizing can be relatively small. Torque characteristics are constant across the overall torque range. The end position switches are set automatically during the setting procedure for the end positions OPEN and CLOSED and need no separate adjustment.

Technical data: operating time for 90° from 8 s to 54 s, swing angles from 80 ° to 100 °, enclosure IP68, corrosion protection KS and ambient temperature from -30 °C to +70 °C. Valve attachments follow the ISO standard. The electrical connection is a manufacturer plug/socket connector, and cable entries are available in different versions.

Safety approvals under IEC 61508 cover safe OPENING/CLOSING (ESD) up to SIL 2 (HFT=0) or SIL 3 (HFT=1) and safe end position feedback up to SIL 2. Under EN ISO 13849 safe end position feedback reaches PL c.

Options are explosion protection, SIL and fire protection. Explosion protection markings: ATEX II2G Ex db eb IIB T4 Gb; FM Class I, Div. 1, Groups C, D T4 and Class I, Zone 1, Group IIB T4; IECEx Ex db eb IIB T4 Gb.

Technical specifications

TypeFail safe unit for open-close duty
SeriesFQM / FQMEx
Torque range150 Nm – 1200 Nm
Operating time for 90°8 s – 54 s
Swing angles80 ° – 100 °
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C – +70 °C
Safe OPENING/CLOSING (ESD), IEC 61508Up to SIL 2 (HFT=0) or SIL 3 (HFT=1)
Safe end position feedbackUp to SIL 2; per EN ISO 13849 up to PL c
ATEX explosion protectionII2G Ex db eb IIB T4 Gb
FM explosion protectionClass I, Div. 1, Groups C, D T4; Class I, Zone 1, Group IIB T4
IECEx (International/Australia)Ex db eb IIB T4 Gb

How it compares with similar models

ParameterFQM / FQMEx Fail Safe Unit for Open-Close Duty, 150 – 1200 NmFQM / FQMEx SIL Fail Safe Unit up to SIL 3, 150 – 1200 NmGST Planetary Spur Gearboxes for SA Multi-Turn Actuators, up to 16000 Nm, IP68GSTI Multi-Turn Gearboxes for Nuclear Power Plants, 2000 – 16000 Nm, IP68
TypeFail safe unit for open-close dutyFail safe unit, SIL version, for open-close dutyPlanetary spur gearboxMulti-turn gearbox for nuclear power plants
Torque range150 Nm – 1200 Nm150 Nm – 1200 Nm0 Nm – 16000 Nm2000 Nm – 16000 Nm
Ambient temperature-30 °C – +70 °C-30 °C – +70 °C-40 °C – +80 °C-25 °C – 80 °C
ATEX explosion protectionII2G Ex db eb IIB T4 GbII2G Ex db eb IIB T4 GbII2G c IIC T4 II2D c T130 °CII2G c IIC T4 II2D c T130 °C

Request a price and lead time

FQM / FQMEx Fail Safe Unit for Open-Close Duty, 150 – 1200 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What drives the valve to its safe position?

Mechanical energy stored in a spring. The spring is not operated during standard operation.

What are the torque, operating time and swing angle ranges?

Torque 150 Nm – 1200 Nm, operating time for 90° from 8 s to 54 s, swing angles from 80 ° to 100 °.

Up to which SIL level are the safety functions approved?

Under IEC 61508, safe OPENING/CLOSING (ESD) reaches SIL 2 (HFT=0) or SIL 3 (HFT=1) and end position feedback reaches SIL 2.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides