International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

GSTI Multi-Turn Gearboxes for Nuclear Power Plants, 2000 – 16000 Nm, IP68

GSTI multi-turn gearboxes operate gate valves and globe valves in nuclear power plants, inside and outside containment, for open-close duty. Torque range 2000 Nm – 16000 Nm, enclosure IP68, LOCA/DBE resistance, IEEE 382-1996 and KTA 3504-2006.

Type
Multi-turn gearbox for nuclear power plants
Series
GSTI
Application
Inside & Outside Containment
Type of duty
Short-time duty S2 - 15 min (open-close)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

GSTI multi-turn gearboxes can be used for operating gate valves and globe valves in nuclear power plants, both inside and outside containment (Inside & Outside Containment). They are intended for open-close duty.

The type of duty is short-time duty S2 - 15 min (open-close duty). Operation modes to choose from are motor operation through an electric multi-turn actuator or manual operation directly with the handwheel.

Design features: suitability for electrical and manual operation, and a solution for special installation conditions. The gearbox is earthquake resistant and withstands LOCA/DBE conditions for a short time at a maximum of 185 °C.

Technical data: torque range from 2000 Nm to 16000 Nm, enclosure IP68, corrosion protection KS, ambient temperature from -25 °C to 80 °C. Valve attachments follow DIN and ISO standards. Compliance: IEEE 382-1996 and KTA 3504-2006. The ATEX marking is II2G c IIC T4 and II2D c T130 °C.

Options are combinations with SAI/SARI or SAN/SARN actuators, and manual operation without an actuator. Advantages: a DBE resistant gearbox, simple installation and easy maintenance.

Technical specifications

TypeMulti-turn gearbox for nuclear power plants
SeriesGSTI
ApplicationInside & Outside Containment
Type of dutyShort-time duty S2 - 15 min (open-close)
Torque range2000 Nm – 16000 Nm
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-25 °C – 80 °C
LOCA/DBE resistanceFor a short time, max. 185 °C
Valve attachmentsDIN and ISO standards
ComplianceIEEE 382-1996, KTA 3504-2006
ATEX explosion protectionII2G c IIC T4 II2D c T130 °C
CombinationsSAI/SARI, SAN/SARN actuators; manual operation without actuator

How it compares with similar models

ParameterGSTI Multi-Turn Gearboxes for Nuclear Power Plants, 2000 – 16000 Nm, IP68GSI Part-Turn Gearboxes for Nuclear Power Plants, 500 – 24000 Nm, IP68GST Planetary Spur Gearboxes for SA Multi-Turn Actuators, up to 16000 Nm, IP68GHT Multi-Turn Gearboxes with Bronze Worm Wheel, up to 120000 Nm, IP68
TypeMulti-turn gearbox for nuclear power plantsPart-turn gearbox for nuclear power plantsPlanetary spur gearboxMulti-turn gearbox
Torque range2000 Nm – 16000 Nm500 Nm – 24000 Nm0 Nm – 16000 Nm0 Nm – 120000 Nm
Ambient temperature-25 °C – 80 °C-25 °C – +80 °C-40 °C – +80 °C-40 °C – +80 °C
Valve attachmentsDIN and ISO standardsDIN and ISO standardsEN ISO 5210EN ISO 5210, EN ISO 5211
ATEX explosion protectionII2G c IIC T4 II2D c T130 °C—II2G c IIC T4 II2D c T130 °CII2G c IIC T3 II2D c T190 °C

Request a price and lead time

GSTI Multi-Turn Gearboxes for Nuclear Power Plants, 2000 – 16000 Nm, IP68. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which valves are GSTI gearboxes meant for?

Gate valves and globe valves in nuclear power plants, inside and outside containment.

What are the torque range and enclosure rating?

Torque from 2000 Nm to 16000 Nm, enclosure IP68 and corrosion protection KS.

What resistance to accident conditions does it have?

The gearbox is earthquake resistant and withstands LOCA/DBE conditions for a short time at a maximum of 185 °C.