KSTAR EPOWER-L — industrial UPS with isolation transformer 10–160 kVA
KSTAR EPOWER-L is an industrial online UPS rated 10–160 kVA with a built-in isolation transformer for harsh operating conditions. The input power factor is up to 0.97, and control is fully DSP-based. Up to 6 UPS operate in parallel.
- Power
- 10–160 kVA
- Phase configuration
- 3:3
- Power factor
- up to 0.97 (input), output 0.8
- Control
- DSP
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
USK ENERGY supplies KSTAR equipment as an official partner of the manufacturer. All KSTAR products
Description
KSTAR EPOWER-L is an industrial three-phase online UPS rated from 10 to 160 kVA with a built-in isolation transformer. Input and output are three-phase (3:3). The series is aimed at harsh operating conditions, primarily industrial use, where there is interference, vibration and an unstable mains.
The input power factor reaches 0.97, so the UPS loads the mains only slightly with a reactive component. The output power factor is 0.8. Control is fully digital, on a DSP, and the topology is online with double conversion. A clean sinusoidal voltage is formed at the output, which suits sensitive equipment and critical applications.
The isolation transformer is built into the case, so it does not have to be selected and installed separately at the site. It galvanically separates the load from the mains, which is useful when the power passes through long lines or is polluted by interference.
To improve availability, the UPS can be connected in parallel, up to 6 units. The battery configuration is flexible and is selected for the required backup time. The UPS performs a self-test, which makes scheduled maintenance easier and helps to detect a fault in time.
When selecting within 10–160 kVA, the load power is checked against the rating and the output power factor of 0.8, and whether parallel redundancy is needed is also decided. The dimensions, weight, battery type and quantity, and communication options are specified on request, because there is no data on them for this series in the available information. The built-in transformer and the digital DSP control make the series suitable for industrial sites where motors and converters operate nearby, since such loads create interference in the mains. The input power factor of up to 0.97 reduces the reactive current the UPS draws from the mains, so the supply lines and the generator are less loaded. Parallel operation of up to 6 UPS makes it possible to increase power as the site develops. The output with a clean sine wave is suitable for sensitive equipment. The power factor of 0.8 at the output must be taken into account when converting kilovolt-amperes to the active power of the load. The backup time is determined by the number of installed batteries and is calculated separately for the site.
Technical specifications
| Power | 10–160 kVA |
|---|---|
| Phase configuration | 3:3 |
| Power factor | up to 0.97 (input), output 0.8 |
| Control | DSP |
| Parallel operation | up to 6 UPS |
Request a price and lead time
KSTAR EPOWER-L — industrial UPS with isolation transformer 10–160 kVA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What power range does KSTAR EPOWER-L have?
The series covers 10–160 kVA with three-phase input and output (3:3). The transformer is built into the case.
What power factors does KSTAR EPOWER-L have?
The input power factor reaches 0.97 and the output one is 0.8. Control is fully digital, on a DSP.
Can KSTAR EPOWER-L be connected in parallel?
Yes, up to 6 UPS operate in parallel. This increases the power availability for critical equipment.