HH ICS® — high-voltage fuses with increased cyclic stability for renewables

HH high-voltage current-limiting fuses with ICS® technology for voltage from 6/12 kV and current from 63 A. The fuse element compensates thermal cycling, and resistance to cyclic switching is more than 40 times higher than in ordinary fuse-links. For wind and solar plants, storage systems and charging infrastructure.

Rated voltage
from 6/12 kV
Rated current
from 63 A
Technology
ICS® (Increased Cyclic Stability), fuse element with thermal cycling compensation
Cyclic stability
more than 40 times higher than in ordinary fuse-links

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

HH fuses with ICS® technology (Increased Cyclic Stability) are a series of high-voltage current-limiting fuses for networks with variable load. Decentralised generation (wind, solar and hydro power plants), high-power energy storage and charging stations create constant load cycles in the network. In ordinary HH fuse-links such cycles lead to premature fatigue of the fuse element material. Maintenance intervals shorten, and a fuse-link can fail suddenly. The reason is that the number of local connection points and of power take-off from renewable sources is growing quickly, and the load in the network varies strongly.

ICS fuse-links have a fuse element of special structure that automatically compensates even strongly varying thermal loads. According to the manufacturer, the resistance to cyclic switching in ICS is more than 40 times higher than in traditional fuse-links. This corresponds to the increased stability recommended by IEC/TR 62655 (guidance on the application of high-voltage fuses). All the properties of current-limiting HH fuse-links are retained, including interruption of the short-circuit current in the first half-cycle, quartz filling, and a striker for tripping the load-break switch.

ICS fuses are produced for rated voltages from 6/12 kV and rated currents from 63 A. The rating plate of SSK/ICS fuse-links shows the class, place of manufacture, rated breaking currents I1 and I3, striker force, rated current and voltage, and the version by environmental conditions. In dimensions the fuse-links are compatible with standard DIN fuse-links (DIN 43625). They are manufactured in Germany. ICS fuse-links are designed for demanding cyclic load currents, at which they retain functionality and durability.

The operational effect is longer inspection intervals, longer service life, lower maintenance costs and protection against system failures. They are used on transformers of wind power installations and collector substations of wind farms, at solar power plants, for connecting energy storage (BESS) and high-power charging stations, and at distribution network substations with a high share of renewable sources.

The rating is chosen in the same way as for standard HH fuse-links: by transformer power and voltage, inrush current and selectivity requirements with the LV protection. If one fuse-link has operated in a three-phase circuit, it is recommended to replace all three.

Technical specifications

Rated voltagefrom 6/12 kV
Rated currentfrom 63 A
TechnologyICS® (Increased Cyclic Stability), fuse element with thermal cycling compensation
Cyclic stabilitymore than 40 times higher than in ordinary fuse-links
Applicationwind, solar, hydro plants, BESS, charging infrastructure
StandardsIEC 60282-1, IEC/TR 62655

Request a price and lead time

HH ICS® — high-voltage fuses with increased cyclic stability for renewables. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What voltage and current are HH fuses with ICS produced for?

For rated voltages from 6/12 kV and rated currents from 63 A.

How many times higher is the cyclic stability compared with ordinary fuse-links?

According to the manufacturer, more than 40 times. This corresponds to the increased stability recommended by IEC/TR 62655.

Are the fuse-links compatible with standard dimensions?

Yes, in dimensions they are compatible with standard DIN fuse-links (DIN 43625).