EVR — SF6 automatic circuit reclosers 15.5–38 kV

EVR-1, EVR-2 and EVR-3 are three-phase automatic reclosers with SF6 insulation and vacuum arc interruption for overhead lines and substations at 15.5, 27 and 38 kV. Interrupting current is 12.5 kA, up to 16 kA in the 38 kV model, and the magnetic actuator is rated for 10,000 operations.

Rated voltage
15.5 / 27 / 38 kV (EVR-1, EVR-2, EVR-3)
Rated current
630/800 A
Breaking current
12.5 kA (38 kV — 12.5/16 kA)
Short-time withstand current
12.5 kA (38 kV — 12.5/16 kA), 3 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The three-phase SF6 reclosers EVR-1, EVR-2 and EVR-3 are installed on overhead lines and substations of the 15.5, 27 and 38 kV classes. The company's product range started with this line. In 1999 the company built a 27 kV SF6 recloser that passed testing at KEMA and received a Korean new-technology certificate. In 2000–2001 models for 15 and 38 kV appeared, including 38 kV / 16 kA, tested at KEMA and CESI.

The arc is extinguished by vacuum interrupters, and the internal insulation is SF6 in a stainless steel tank. The bushings are epoxy with a silicone housing. The tank and the control cabinet withstand heat, humidity, dust and corrosion. The drive uses a permanent magnet actuator without mechanical latches and is rated for 10,000 operations without maintenance, while the small number of moving parts lowers installation and operating costs.

Rated current is 630/800 A, frequency 50/60 Hz. Breaking current and 3 s short-time withstand current are 12.5 kA, and for 38 kV 12.5 or 16 kA. Making capacity is 32.5 kA, and 32.5/40 kA for the 38 kV unit. The recloser interrupts a cable charging current of 5 A and a transformer magnetizing current of 22 A (22/28 A for 38 kV). The insulation withstands up to 170 kV impulse voltage, 70 kV power frequency dry and 45 kV wet.

The delivery includes resistive (1 %) and capacitive (2.5 %) voltage dividers, CTs for the whole protection range and manual tripping. The 18 A·h battery is rated for hundreds of operations over 30 hours after the external 110/220 V AC supply is lost. The device itself operates at −40…+80 °C, the controller at −25…+70 °C, degree of protection IP55.

The controller ETR300-R or EVRC2A-NT measures, monitors, records events and transmits data over DNP 3.0, MODBUS and IEC 60870-5-101/104. It supports the IEEE C37.112, IEC 255-3 and McGraw Edison curves. The recloser is mounted on a pole or at a substation with a full set of cables and brackets. Testing was carried out at KEMA, CESI or KERI to ANSI C37.60 and IEC 62271-111. The device sectionalizes overhead feeder lines, automatically restores supply after temporary faults and fits into distribution network automation schemes.

Technical specifications

Rated voltage15.5 / 27 / 38 kV (EVR-1, EVR-2, EVR-3)
Rated current630/800 A
Breaking current12.5 kA (38 kV — 12.5/16 kA)
Short-time withstand current12.5 kA (38 kV — 12.5/16 kA), 3 s
Making capacity32.5 kA (38 kV — 32.5/40 kA)
Interruptioncables 5 A; transformer magnetizing 22–28 A
Insulationup to 170 kV impulse; 70 kV dry, 45 kV wet
Drivemagnetic actuator, 10,000 operations
Temperature−40…+80 °C
Degree of protectionIP55
StandardsANSI C37.60, IEC 62271-111

Request a price and lead time

EVR — SF6 automatic circuit reclosers 15.5–38 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 21 00 00
HS, 6 digits8535 21
CN (EU)8535 21 00
HTSUS (USA)8535 21 00 00
China customs tariff8535 21 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What breaking current do EVR reclosers have?

For 15.5 and 27 kV the breaking current is 12.5 kA, for 38 kV 12.5 or 16 kA. Making capacity is 32.5 kA, up to 40 kA in the 38 kV version.

How does EVR differ from a solid insulated recloser?

In EVR the internal insulation is SF6 in a stainless steel tank, and the bushings are epoxy with a silicone housing. The arc is still extinguished by vacuum interrupters, degree of protection IP55.

Which protection curves does the EVR controller support?

The ETR300-R or EVRC2A-NT controller supports the IEEE C37.112, IEC 255-3 and McGraw Edison curves. Communication runs over DNP 3.0, MODBUS and IEC 60870-5-101/104.