EcoLink — single-phase self-powered recloser for fuse cutout holders, 15.5 kV, 200 A

EcoLink is a single-phase vacuum recloser rated 15.5 kV and 200 A, installed in a standard overhead line fuse cutout holder in place of a fuse link. The device is fully self-powered and brings auto-reclosing to rural and remote lines with low load currents.

Model
ECL15-4-200-501
Maximum operating voltage
15.5 kV
Rated current
200 A
Minimum operating current
0.15 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

EcoLink is designed for rural and remote distribution lines with low load currents. Such lines are usually protected by fuses. EcoLink is fitted in the same holder, and the line gains an auto-reclose function with minimal installation cost. The device suits most fuse holders, and its weight of 16.3 lb makes installation easier.

There are no batteries. The device draws energy from the line current, and the storage element is a supercapacitor array that charges quickly and does not degrade the way batteries do. Charge is accumulated from the same line current, so after the line is energised the device is quickly ready for operation. A primary current of 0.15 A is enough for operation, and the minimum protection pickup setting is 1 A. Fast protection is provided for switching onto an existing fault. The operating temperature range is from −40 to 131 °F.

The patented switch-lock handle is arranged so that, before EcoLink is removed from the holder, the internal vacuum interrupter breaks the line current. No external arc occurs during removal, and the lineman works with a device through which current no longer flows.

The ECL15-4-200-501 model has a maximum operating voltage of 15.5 kV, a short-circuit breaking current of 4 kA, a short-circuit making current of 10.4 kA (peak) and a short-time withstand current of 4 kA for 3 s. The lightning impulse withstand voltage is 110 kV, and the power-frequency withstand voltage, dry and wet, is 50 kV. Mechanical endurance is 2000 operations, and 300 operations at maximum breaking current. The auto-reclose duty cycle is O–0.1 s–CO–1 s–CO–1 s–CO, the frequency is 50 / 60 Hz and the design service life is 15 years. The device complies with IEEE C37.60 and IEC 62271-111.

Settings are entered in the EcoLink app over a secure encrypted wireless connection with role-based access. The requirements of the IEEE 1686 cybersecurity standard were taken into account in the design. Setting sets are stored and managed centrally using Excel templates, which is convenient for a network company with a large fleet of such devices.

Technical specifications

ModelECL15-4-200-501
Maximum operating voltage15.5 kV
Rated current200 A
Minimum operating current0.15 A
Minimum protection pickup current1 A
Rated short-circuit breaking current4 kA
Short-circuit making current (peak)10.4 kA
Short-time withstand current4 kA – 3 s
Lightning impulse withstand voltage (BIL)110 kV
Power-frequency withstand voltage50 kV
Mechanical endurance2000 operations
Auto-reclose duty cycleO – 0.1 s – CO – 1 s – CO – 1 s – CO
Frequency50 / 60 Hz
Service life15 years
StandardsIEEE C37.60, IEC 62271-111

Request a price and lead time

EcoLink — single-phase self-powered recloser for fuse cutout holders, 15.5 kV, 200 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 21 00 00
HS, 6 digits8535 21
CN (EU)8535 21 00
HTSUS (USA)8535 21 00 00
China customs tariff8535 21 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

From what line current does EcoLink operate?

A primary current of 0.15 A is enough, and the minimum protection pickup setting is 1 A. There are no batteries, and energy is stored in supercapacitors.

What are the breaking parameters of EcoLink?

The ECL15-4-200-501 model, 15.5 kV and 200 A, breaks a short-circuit current of 4 kA and has a short-circuit making current of 10.4 kA (peak). Mechanical endurance is 2000 operations.

What standards does EcoLink comply with?

IEEE C37.60 and IEC 62271-111. The IEEE 1686 cybersecurity standard was taken into account in the design.