International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

DOM / AOM digital and autonomous operating mechanisms with remote control (IEC 61850)

Operating mechanisms with a built-in RTU: digital DOM for integration into substation SCADA per IEC 61850, and autonomous AOM for sites without auxiliary supply. The AOM runs on a 24 V DC battery with a solar panel and is controlled via GSM/GPRS.

DOM
RTU, IEC 61850 and IEC 62271-3, MODBUS, optionally DNP3, IEC 60870-5, optical output
AOM
24 V DC battery with a solar panel, control via GSM/GPRS
Functions
state monitoring, comparison with the motor reference curve, alarm signalling

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The DOM supports IEC 61850 and IEC 62271-3, MODBUS, optionally DNP3 and IEC 60870-5, and has an optical output. The mechanism monitors the state of the unit and compares motor operation with a reference curve, giving an alarm on deviation. The AOM is designed for sites with no auxiliary supply and runs on its own battery.

Technical specifications

DOMRTU, IEC 61850 and IEC 62271-3, MODBUS, optionally DNP3, IEC 60870-5, optical output
AOM24 V DC battery with a solar panel, control via GSM/GPRS
Functionsstate monitoring, comparison with the motor reference curve, alarm signalling

Request a price and lead time

DOM / AOM digital and autonomous operating mechanisms with remote control (IEC 61850). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 10 98 90
HS, 6 digits8537 10
CN (EU)8537 10 98
HTSUS (USA)8537 10 91 70
China customs tariff8537 10 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What protocols does the DOM mechanism support?

IEC 61850 and IEC 62271-3, MODBUS, optionally DNP3 and IEC 60870-5, with an optical output.

How is the autonomous AOM mechanism powered?

From a 24 V DC battery with a solar panel, controlled via GSM/GPRS.

What diagnostic functions do the mechanisms have?

State monitoring, comparison of operation with the motor reference curve, and alarm signalling.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides