Power transformers up to 765 kV, 1500 MVA

Power transformers, extra-high-voltage, up to 765 kV and with a rating up to 1500 MVA. They are installed at substations and power plants, in railway power supply, in metallurgy and at data centers.

Voltage
up to 765 kV
Power
up to 1500 MVA
Design
indoor and outdoor installation
Monitoring
online UHF PD, hot-spot temperature, DGA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The transformers are made at the manufacturer's plant in Changwon, in indoor and outdoor designs. The scope of supply can include online monitoring of partial discharges by UHF, hot-spot temperature and dissolved gases (DGA). Standards are chosen to the requirements of the country of supply, IEC, ANSI, IEEE and others. For 765 kV networks and large generating units this is a class of equipment where condition monitoring is built in at the design stage.

Technical specifications

Voltageup to 765 kV
Powerup to 1500 MVA
Designindoor and outdoor installation
Monitoringonline UHF PD, hot-spot temperature, DGA
Standardsto the requirements of the supply countries (IEC, ANSI, IEEE and others)

Replacement for

ТРДЦН-160000/220, АТДЦТН-200000/220/110, АТДЦТН-200000/330/110, АОДЦТН-167000/500/220, ТЦ-630000/500, АОДЦТН-333000/750/330

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Power transformers up to 765 kV, 1500 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 29 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage and power are the power transformers built for?

Up to 765 kV and up to 1500 MVA.

What condition monitoring is available for the transformers?

Online monitoring of partial discharges by UHF, hot-spot temperature and dissolved gases (DGA).

Which standards are the power transformers made to?

To the requirements of the country of supply, including IEC, ANSI and IEEE.