Traction transformers and traction substation autotransformers
Traction transformers from the manufacturer for rolling stock and autotransformers for railway traction substations. On-board units are installed on locomotives and electric trains, stationary ones supply the overhead contact line.
- On-board
- for locomotives and electric trains, supplied from the contact line
- Stationary
- traction substation autotransformers feeding the contact line
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
An on-board traction transformer is fed from the overhead contact line and is mounted directly on the locomotive or electric train. Traction substation autotransformers work on the stationary side and supply the railway contact line. Both groups are produced as separate items, and frequency, voltage and power are stated for the specific rolling stock or substation.
Technical specifications
| On-board | for locomotives and electric trains, supplied from the contact line |
|---|---|
| Stationary | traction substation autotransformers feeding the contact line |
Replacement for
ОДЦЭ-5000/25, ОНДЦЭ-4350/25, ОЦР-5600/25 (traction, for electric locomotives); ТДТНЖ-25000/110, ТДТНЖ-40000/110, ТДТНЖ-40000/220, ТМЖ-400/27,5
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Traction transformers and traction substation autotransformers. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 2 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which rolling stock are the traction transformers made for?
For locomotives and electric trains supplied from the overhead contact line.
Is there equipment for the stationary part of the traction network?
Yes, traction substation autotransformers, which supply the contact line.
What data is needed to order a traction transformer?
The frequency and voltage of the contact line, the power, and the type of rolling stock or substation; numerical parameters are not given in the series card.
Similar equipment from other manufacturers