International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TES-OM / TES-ORR — oil distribution transformers (hermetically sealed and with conservator)

TES-OM and TES-ORR oil transformers are made in a hermetically sealed design and with an oil conservator. They work indoors and outdoors, including heavily polluted areas, and are used in distribution networks, industry, mining and the oil and gas sector.

Design
sealed; with conservator
Execution examples
TES-OM 315 kVA 30/0.4 kV; TES-ORR3-2 630 kVA 20/0.4 kV
Vector group
Dyn11
Regulation
DETC ±2×2.5 %

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Oil transformers of this series allow many configurations and installation methods, indoors and outdoors, including heavily polluted areas. They are especially valued for outdoor installation. According to the manufacturer, more than 10 000 of its oil transformers are in operation worldwide.

Two main designs are made. The hermetically sealed one has a completely filled tank without a conservator, and the other design is fitted with a conservator. A typical package includes LV and HV bushings, an off-circuit tap changer (DETC) and an earthing terminal. Accessories are mounted and wired at the factory to simplify installation and maintenance and to cut costs. Dimensions and terminal positions are optimized for limited space.

For extreme environmental conditions, a special anti-corrosion coating and stainless steel bolts are used. Designs for seismic zones and installations with a high level of vibration are available. Filling with eco-friendly fluids is possible. Examples of executions include TES-OM 315 kVA, 30/0.4 kV, Dyn11, 50 Hz, regulation ±2×2.5 %, and TES-ORR3-2 630 kVA, 20/0.4 kV, Dyn11. The manufacturer's oil transformer range reaches 50 MVA and insulation class 145 kV (BIL 650 kV), and large units with OLTC are described in a separate entry.

Routine tests cover measurement of winding resistance, transformation ratio, vector group, dielectric strength, no-load losses and current, short-circuit voltage and losses, and a check of accessories. Type tests are carried out for lightning impulse, temperature rise and noise level, and special tests for short-circuit withstand under IEC 60076. The company's environmental management system is certified to ISO 14001:2015 by DNV Business Assurance Italy. The scope of the certificate covers design, manufacture and testing of oil-filled, dry-type and cast resin transformers, reactors and autotransformers. The transformers are used in distribution networks, industry, mining and oil and gas facilities, PV plants, hydropower plants and geothermal stations.

The hermetically sealed design is convenient because the tank is closed and the oil does not contact air, so no care of the conservator and air dehydrating breather is needed. The design with a conservator remains the familiar choice when visual control of the oil level is required.

Technical specifications

Designsealed; with conservator
Execution examplesTES-OM 315 kVA 30/0.4 kV; TES-ORR3-2 630 kVA 20/0.4 kV
Vector groupDyn11
RegulationDETC ±2×2.5 %
Frequency50 Hz
Installationindoor and outdoor, polluted areas
Corrosion protectionspecial coating, stainless steel fasteners
StandardsIEC 60076

Replacement for

ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТМГ-…/35, ТМ-1000/35…ТМ-2500/35, ТМН-4000/35, ТМН-6300/35

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

TES-OM / TES-ORR — oil distribution transformers (hermetically sealed and with conservator). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which designs of TES-OM and TES-ORR oil transformers are available?

A hermetically sealed design without a conservator with a completely filled tank, and a design with a conservator. Both work indoors and outdoors.

What voltages and vector group do the series examples have?

TES-OM 315 kVA is 30/0.4 kV, TES-ORR3-2 630 kVA is 20/0.4 kV, both with Dyn11. Regulation with the off-circuit tap changer is ±2×2.5 %, frequency 50 Hz.

What rating and insulation class does the oil transformer range reach?

The manufacturer's oil transformer range reaches 50 MVA and insulation class 145 kV with BIL 650 kV. Tests are carried out under IEC 60076.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides