A range of liquid-immersed distribution transformers up to 5 MVA with a grain-oriented CRGO steel core, meeting Ecodesign Tier 2. The high voltage is 6.6, 11 or 33 kV and the low voltage 433 or 690 V. Used in industry, ports, water utilities, data centres and energy storage systems.

Rating
up to 5 MVA (standard 315–3000 kVA)
HV voltage
6.6; 11; 33 kV
LV voltage
433 V, 690 V or other
Core
cold-rolled grain-oriented steel (CRGO)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

T2 Ecotrans is a range of distribution transformers with a core of cold-rolled grain-oriented steel (CRGO), intended for budget-constrained projects while meeting the Ecodesign Tier 2 loss requirements. The transformers are liquid-filled. They are filled with mineral oil (ONAN cooling) or with synthetic or natural ester (KNAN) for sites with increased fire safety requirements.

The range is up to 5 MVA with a high voltage of 11, 6.6 or 33 kV and a low voltage of 433 V, 690 V or any other to order. Standard stock versions at 11 000/433 V have ratings of 315, 500, 800, 1000, 1250, 1500, 1600, 2000, 2500 and 3000 kVA. The vector group is Dyn11, the windings are aluminium, the HV taps are +5, +2.5, 0, −2.5 and −5 %, and breathing is free or a hermetically sealed tank. No-load/load losses at 75 °C are 324/2800 W for 315 kVA and 1885/21 960 W for 3000 kVA.

For each rating there is an ONAN/KNAN datasheet and a general arrangement drawing, including with RMUs and LV cabinets mounted, that is, a turnkey layout. Unit type versions (HV and LV terminals on one side) and large distribution transformers for BESS up to 5 MVA with a split LV winding are possible. Stock availability shortens delivery times, and to order the design can be fully adapted to the site.

According to the general arrangement drawings, the unit is equipped with a five-position off-circuit tap changer with a sealing facility, a thermometer pocket, an oil level indicator, an earthing terminal for an M12 bolt and a skid base with holes for transport. The 12 kV HV cable box is three-pole, with heat-shrink insulation, for one three-core cable of up to 185 mm². Painting is to BS 381C (shade 632) and ISO 12944, not lower than C4H, and the top-oil temperature rise above ambient is 40 °C.

Deliveries include seven T2 1500 kVA transformers for the DP World Southampton port, a T2 1600 kVA 11–6.6/0.433 kV transformer for a Thames Water pumping station, 2–2.8 MVA 11/0.417 kV KNAN transformers for a data centre in Peterborough, and forty 2.8 MVA 33/0.48 kV transformers for the Pillswood BESS (98 MW / 196 MWh, Tesla Megapack). Applications are industry, ports, water utilities, data centres, energy storage systems and commercial property. The standard is IEC 60076.

Technical specifications

Ratingup to 5 MVA (standard 315–3000 kVA)
HV voltage6.6; 11; 33 kV
LV voltage433 V, 690 V or other
Corecold-rolled grain-oriented steel (CRGO)
Windingsaluminium
HV taps±2×2.5 %
CoolingONAN (mineral oil) or KNAN (ester)
Vector groupDyn11
No-load / load losses at 75 °C324/2800 W (315 kVA); 1885/21 960 W (3000 kVA)
EfficiencyEcodesign Tier 2
StandardsIEC 60076

Replacement for

ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТМГ-…/35, ТМ-1000/35…ТМ-2500/35, ТМН-4000/35, ТМН-6300/35; energy-efficient ТМГ11, ТМГ12

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

T2 Ecotrans — oil-filled Tier 2 distribution transformers up to 5 MVA, 6.6–33 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which stock ratings are available in the T2 Ecotrans range?

Standard versions at 11 000/433 V have ratings of 315, 500, 800, 1000, 1250, 1500, 1600, 2000, 2500 and 3000 kVA. The overall range is up to 5 MVA.

How do the ONAN and KNAN versions differ?

ONAN means filling with mineral oil, KNAN with synthetic or natural ester for sites with increased fire safety requirements. There is an ONAN/KNAN datasheet for each rating.

What losses do T2 Ecotrans transformers have?

No-load and load losses at 75 °C are 324/2800 W for 315 kVA and 1885/21 960 W for 3000 kVA. The level meets Ecodesign Tier 2.